Symbol MK1000 Product Reference Manual page 208

Hide thumbs Also See for MK1000:
Table of Contents

Advertisement

MK1000 MicroKiosk Product Reference Guide
Problem
10.MK1000 will not
communicate over a wired-
Ethernet connection.
F-10
Table F-1. Troubleshooting (Continued)
Possible Causes
Unit does not support a
wired Ethernet
connection.
Possible Solutions
1. Confirm your unit supports a
wired Ethernet connection.
- Find the model number (see sticker
attached on the back of the unit).
The model number structure is
MK1000-xxx???xxxxx. To support a
wired Ethernet connect, one of the
following designations must be
present: RSE, RFR, AL1, AL2 or
AL3.
(continued)
2. Determine the MK1000's IP
Address.
- Press the '4' and '1' buttons on the
unit simultaneously (an Enter
Password screen appears).
- Type in '44213' (System menu
screen appears).
- Scroll the cursor (<) down to
Network by pressing the '3' button.
- With the cursor on Network, press
'4' (Network Configuration screen
appears).
- Scroll the cursor down to Ethernet
by pressing '3' twice.
- With the cursor on Ethernet, press
'4' (Ethernet Configuration screen
appears).
- The 4th line shows the MK1000's
wired IP Address - record it on a
sheet of paper.
- The factory default wired IP
Address is 192.168.0.1.