5
The Read processing completes
and the result is reflected on the
WebLink screen.
6
EIPInput.DECODE_LENGTH
and EIPInput.DECODE_DATA
will display the following for this
example string.
<Decoded String: 123456>
EIPInput.DECODE_LENGTH: 6
EIPInput.DECODE_DATA[0]: 31(1)
EIPInput.DECODE_DATA[1]: 32(2)
EIPInput.DECODE_DATA[2]: 33(3)
EIPInput.DECODE_DATA[3]: 34(4)
EIPInput.DECODE_DATA[4]: 35(5)
EIPInput.DECODE_DATA[5]: 36(6)
DECODE_DATA should be set to
output in ASCII.
7
When DECODE_DATA is used to
change the display format to ASCII,
the Decoded String can be easily
confirmed.
* To check the string in ASCII, you
need to set the data type of
S_EIPInput103-DECODE_DATA
to Array [0 .. 435] OF BYTE.
7. EtherNet/IP Connection Procedure