6
Click in the Target Variable
field for Input.
Press the Ctrl + Space Keys on
the keyboard to display
available assembly numbers.
* Entering even the first
character 1 displays a list of
matching assembly numbers.
Select the assembly number.
In the same way, select the
Target Variable field for
Output.
7
Click in Originator Variable
field for Input.
A list of available tag set names
is displayed. Select the one to
use.
In the same way, set the
Originator Variable field for
Output.
8
Set the Connection Type,
RPI[ms], and Timeout Value
fields as needed.
9
Confirm that 2 is shown for
Connections.
7. EtherNet/IP Connection Procedure
39