Omron V330-F Series Connection Manual page 16

Auto focus multi code reader
Hide thumbs Also See for V330-F Series:
Table of Contents

Advertisement

■ EIPInput Structure
Code reader data
INFO BIT
Reserved for future use EIPInput. RESERVED1
Reserved for future use EIPInput. RESERVED2
Reserved for future use EIPInput. RESERVED3
Status Signal (32 bits)
Error code
Read Count Information EIPInput. COUNTERS
Read Cycle Report
Decode Cycle Report
Read Symbol Type
Read Symbol PPE
Decoded String Length
Decoded String
*1. Control Signal Assignment
Variable: EIPInput.Device_status Assignment
15
14
13
12
31
30
29
28
RunMode: ON when in Read Cycle
Trigger Acknowledge: ON when Output Assembly Trigger Bit is received
Decoding: ON while image is being processed
DataIsReady: ON when Data Output and Judgment are verified
Precautions for Correct Use
If the data size of the code reader's tag data link data is an odd number of bytes, declare it
as BYTE instead of BOOL.
Variable name
EIPInput.INFO_BITS
EIPInput.DEVICE_STATUS
EIPInput. FAULT
EIPInput.
READ_CYCLE_REPORT
EIPInput.
DECODE_CYCLE_REPORT
EIPInput. CODE_TYPE
EIPInput.PIXELS_PER_ELEMENT REAL
EIPInput. DECODE_LENGTH
EIPInput DecodeData
11
10
9
8
7
27
26
25
24
23
6. EtherNet/IP Settings
Data type
BYTE
BYTE
BYTE
BYTE
*1
BOOL[32]
DINT
DINT[6]
INT[4]
INT[4]
DINT
DINT
BYTE[436]
6
5
4
3
2
DataIs
Deco
Ready
ding
22
21
20
19
18
1
0
Trigger
Run
Acknow
Mode
ledge
17
16
15