The status of the power supply is indicated by a green LED:
Device type SCALANCE
X204RNA (HSR)
X204RNA EEC (HSR)
X204RNA EEC (PRP/HSR)
If configured as HSR device.
1. Both L power supplies are connected
(redundant supply).
2. One L power supply is connected
(non-redundant supply).
3. Power supply L1 and L2 are not connected or supply voltages are <14 V.
4. Power supply L is connected
5. Power supply L is not connected or the supply voltage is too low.
5.9.2.3

Port LED

The LEDs signal the following port statuses of the SCALANCE X-200RNA (HSR).
The status of the ports is indicated by two-color LEDs:
Device type SCALANCE
X204RNA (HSR)
X204RNA EEC (HSR)
X204RNA EEC (PRP/HSR)
If configured as HSR device.
1. TP link exists, no data reception.
2. TP link, data received at TP port.
3. Device startup, the LED is lit for approx. 6 seconds.
4. Setting or display of the fault mask.
5.9.2.4

LED displays during startup

When the SCALANCE X-200RNA (HSR) starts up, the following LED displays light up in the order
shown:
1. Power LEDs (green) light up immediately after turning on the power.
2. Port LEDs go off, the red error LED is lit for approx. 10 seconds.
SCALANCE X-200RNA
Operating Instructions, 04/2022, C79000-G8976-C342-07
LED lit green
1
4
4
Number of LEDs
2 port LEDs
2 PRP port LEDs
2 port LEDs
2 PRP port LEDs
2 port LEDs
2 PRP port LEDs
LED lit yellow
2
-
-
LED lit green
LED lit yellow
1
2, 3
1
2, 3
1
2, 3
1
2, 3
1
2, 3
1
2, 3
Device description
5.9 LEDs
LED not lit
3
5
5
LED flashes yel‐
low
4
4
4
4
4
4
55