Functional description and configuration using Web Based Management
9.10 The "Switch" menu
9.10.6.4

PRP Statistic

PRP Statistic
The "PRP Statistic" dialog box shows interesting statistical data for the PRP protocol. The
following events are distinguished:
• "Received A Frames at PRP A Port"
Number of valid A frames received at port PRP A.
• "Received B Frames at PRP B Port"
Number of valid B frames received at port PRP B.
• "Received B Frames at PRP A Port"
Number of B frames received at port PRP A (error).
• "Received A Frames at PRP B Port"
Number of A frames received at port PRP B (error).
If you click the "Reset Counters" button, you reset this counter for all ports.