Supervision Frames - Siemens SIMATIC NET SCALANCE X-200RNA Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SIMATIC NET SCALANCE X-200RNA:
Table of Contents

Advertisement

Functional description and configuration using Web Based Management
9.8 The "X200" menu
"Duplicate Aging Time"
The default value from the HSR standard is 400 ms. This value cannot be changed.
"Limitation" / "Max Throughput"
By selecting the "Limitation Enabled" check box, the data throughput from the interlinks to the
HSR ports is limited to the set value. The limitation can be specified with "Max Throughput". A
limitation between 50% and 80% is possible. If the load on the interlinks is greater than the value
set, frames are discarded. This occurs regardless of Ethertypes and any VLAN priorities.
9.8.4

Supervision Frames

In the "Supervision Frames" dialog box, you enable/disable sending of Supervision Frames per
port.
Figure 9-19
Supervision Frames
Send Supervision Frames on Port
Select the check box for the ports at which you want to send Supervision Frames.
When the check box for a port is cleared, neither are own Supervision Frames sent to this port
nor are Supervision Frames that were received at different ports forwarded to this port.
110
Operating Instructions, 04/2022, C79000-G8976-C342-07
SCALANCE X-200RNA