Functional description and configuration using Web Based Management
9.8 The "X200" menu
Figure 9-22
Fault Mask Link Up Monitoring
Enable Link Up Monitoring
Select the check boxes of the ports whose connection status you want to monitor. If link
monitoring is activated, an error is signaled when there is a valid link at this port because, for
example, the cable should not be plugged in.
An error/fault can be signaled in the following ways depending on the configuration of the
SCALANCE X-200RNA: Signaling contact, fault LED, SNMP trap, entry in the log table and the
syslog.
114
Operating Instructions, 04/2022, C79000-G8976-C342-07