Siemens SCALANCE X-200 Configuration Manual

Siemens SCALANCE X-200 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-200:
Table of Contents

Advertisement

SCALANCE X-200
SIMATIC NET
Industrial Ethernet switches
SCALANCE X-200
Configuration Manual
03/2015
C79000-G8976-C285-06
___________________
Preface
___________________
Network topologies and
media redundancy
___________________
IRT communication with X-
200
___________________
Assignment of an IP address
___________________
Configuration using WBM
and CLI
___________________
Menus in the WBM
___________________
Configuration via SNMP
___________________
Connection to PROFINET IO
___________________
Downloading firmware
___________________
MIBs for X-200
___________________
Default ring ports
1
2
3
4
5
6
7
8
A
B

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE X-200

  • Page 1 ___________________ SCALANCE X-200 Preface ___________________ Network topologies and media redundancy ___________________ IRT communication with X- SIMATIC NET ___________________ Assignment of an IP address Industrial Ethernet switches SCALANCE X-200 ___________________ Configuration using WBM and CLI ___________________ Menus in the WBM Configuration Manual...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Purpose of the Configuration Manual This manual supports you when configuring the SCALANCE X-200 Industrial Ethernet switches. It outlines the technical options provided by a SCALANCE X-200 and describes how to configure with Web Based Management (WBM) and the Command Line Interface (CLI).
  • Page 4 Unless mentioned otherwise, the descriptions in these operating instructions refer to all devices of the SCALANCE X-200 product line named above in the section on Validity. In the remainder of the instructions, these will also be referred to as IE switches or also simply as X-200.
  • Page 5 SNMP. You would like information about the IRT technology IRT communication with X-200 (Page 29) with SCALANCE X-200. You want to know how you can use the options of Connection to PROFINET IO (Page 155) PROFINET IO for a connected IE switch.
  • Page 6: Configuration Manual, 03/2015, C79000-G8976-C285

    Preface Where to find Siemens documentation ● Article numbers You will find the article numbers for the Siemens products of relevance here in the following catalogs: – SIMATIC NET - Industrial Communication / Industrial Identification, catalog IK PI – SIMATIC - Products for Totally Integrated Automation and Micro Automation, catalog...
  • Page 7 ● On the Internet under the following entry ID: 50305045 (http://support.automation.siemens.com/WW/view/en/50305045) Trademarks The following and possibly other names not identified by the registered trademark sign ® registered trademarks of Siemens AG: SIMATIC NET, SCALANCE, C-PLUG, OLM License conditions Note Open source software Read the license conditions for open source software carefully before using the product.
  • Page 8 Preface SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 9: Table Of Contents

    Passwords ..........................59 5.1.8 Select/Set Button ........................60 5.1.9 Event log ..........................62 5.1.10 C-PLUG ..........................64 The X-200 menu ........................67 5.2.1 X-200............................67 5.2.2 Fault Mask ..........................69 5.2.3 Ring ............................71 SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 10 Configuring the topology in STEP 7 ..................161 Configuring HRP ........................163 Structure of the data records ....................165 7.5.1 Data record 4 ........................165 7.5.2 Data record 5 ........................166 7.5.3 Data record 0x802A ......................167 SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 11 Regular firmware download ....................171 Loading firmware using the boot loader................172 MIBs for X-200 ............................ 173 Important MIB variables ......................173 Important private MIB variables .................... 175 Default ring ports ..........................177 Index..............................179 SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 12 Table of contents SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 13: Network Topologies And Media Redundancy

    Make sure that the maximum permitted cable lengths for the relevant devices are not exceeded. You will find information about the permitted cable lengths in the Technical specifications section in the operating instructions. Bus topology Figure 1-1 Electrical / optical linear topology with X-100 SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 14 Network topologies and media redundancy 1.1 Network topologies Star topology Figure 1-2 Electrical star topology. Example with X208 Figure 1-3 Star topology with X310 and X208 SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 15 Network topologies and media redundancy 1.1 Network topologies Ring topology Figure 1-4 Optical ring, example with X-200 or X-400 as redundancy manager Figure 1-5 Electrical ring, example with X208 or X-400 as redundancy manager SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 16 Network topologies and media redundancy 1.1 Network topologies Figure 1-6 Electrical and optical ring sections, example with X206-1, X208 or X204-2 as redundancy manager Figure 1-7 Optical ring, example with X202-2IRT SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 17 To increase availability, optical or electrical bus topologies made up of X-200 IE switches with a redundancy manager can be closed to form a ring. The following IE switches can be configured as the redundancy manager: ● SCALANCE X-200 ● SCALANCE X-300 ● SCALANCE X-400 ●...
  • Page 18: Options Of Media Redundancy

    There are various options available to increase the network availability of an Industrial Ethernet network with optical or electrical linear bus topologies: ● Mesh networks ● Parallel connection of transmission paths ● Closing a linear bus topology to form a ring topology SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 19: Media Redundancy In Ring Topologies

    In STEP 7 and on the S7 Ethernet CP modules themselves, the ring ports are indicated by an "R" after the port number. Note Before physically closing the ring, download the configuration of your STEP 7 project to the individual devices. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 20 ● HRP (High Speed Redundancy Protocol) Reconfiguration time: 0.3 seconds ● MRP (Media Redundancy Protocol) Reconfiguration time: 0.2 seconds The mechanisms of these methods are similar. HRP and MRP cannot be used in the ring at the same time. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 21: Mrp

    ● MRP is supported in ring topologies with up to 50 devices. Except in PROFINET IO systems, topologies with up to 100 SCALANCE X-200 and SCALANCE X-300 IE switches were tested successfully. Exceeding this number of devices can lead to a loss of data traffic.
  • Page 22 ● One device in the ring is acting as redundancy manager. ● All other devices in the ring are redundancy clients. Non MRP-compliant devices can be connected to the ring via a SCALANCE X switch or via a PC with a CP 1616. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 23: Mrpd

    MRPD. If you activate MRP in STEP 7, products capable of IRT and MRPD use MRPD automatically. The "High Performance" version of IRT must be used and the topology of the network must be configured. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 24: Hrp

    The following conditions must be met for problem-free operation with HRP: ● HRP is supported in ring topologies with up to 50 devices. In topologies with SCALANCE X-200 and SCALANCE X-300 IE switches, up to 100 nodes are supported. Exceeding this number of devices can lead to a loss of data traffic.
  • Page 25: Redundant Coupling Of Network Segments

    If the standby function is enabled, this is signaled on X-200IRT IE switches by the RM LED. A SCALANCE X-200IRT can be operated either as redundancy manager or in standby mode. The following figure shows the redundant link of SCALANCE X-200 rings with two SCALANCE X-200IRT devices: Figure 1-10...
  • Page 26 If this link fails (for example due to a link-down or a device failure), the slave activates its link as long as the problem persists. Reconfiguration takes place within 0.3 s. See also Standby (Page 76) SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 27: Spanning Tree, Media Redundancy And Passive Listening

    . Since passive listening supports the forwarding of STP BPDUs, there are no circulating frames. ① ② Permitted connection of an STP segment to a Incorrect connection of an STP segment to a ring ring SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 28 Network topologies and media redundancy 1.8 Spanning tree, media redundancy and passive listening SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 29: Irt Communication With X-200

    IRT mode. IRT mode is not possible when the mirroring function is enabled. Supported devices and firmware versions Topology-based IRT requires special network components that support planned data transmission. The following devices of the SCALANCE X-200 product line support topology- based IRT: ● X200-4P IRT ●...
  • Page 30 Based on this information and the other configuration data, STEP 7 calculates the optimized sequence of the IRT communication and the resulting update time. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 31 IO controller and IO device, however, without the best possible synchronicity. Unsynchronized IO device automatically exchange data using RT communication. Since TCP/IP communication is also possible, other non real-time data or configuration/diagnostic data can be transported. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 32 IRT communication with X-200 SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 33: Assignment Of An Ip Address

    ID, the IP address can be assigned to a specific address class. IP address range Max. number of Max. number of Class CIDR notation networks hosts/network 1.x.x.x to 126.x.x.x 16777214 128.0.x.x to 191.255.x.x 16383 65534 192.0.0.x to 223.255.255.x 2097151 Multicast groups Reserved for experiments SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 34 For packet switching here, only the entire IP address is of interest. Note In the bit representation of the subnet mask, the "ones" must be set left-justified; there must be no "zeros" between the "ones". SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 35: Initial Assignment Of An Ip Address

    ● With the STEP 7 configuration tool ● With the NCM PC configuration tool ● With the Primary Setup Tool (PST) configuration tool You will find the PST on the Internet pages of Siemens Industry Online Support under the following entry ID 19440762 (http://support.automation.siemens.com/WW/view/en/19440762).
  • Page 36 Assignment of an IP address 3.2 Initial assignment of an IP address SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 37: Configuration Using Wbm And Cli

    Web Based Management before turning off the device. This ensures that all configuration changes are saved. Note To use SNMP Management and traps, you require a network management station. This does not ship with the IE switch. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 38: Web Based Management

    ● All the pages of the WBM require JavaScript. You should therefore make sure that Java Script is enabled in your browser settings. ● WBM is HTTP- or HTTPS-based, so you must also allow access to port 80 or 443 if you have a firewall installed. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 39: Starting The Wbm And Logging In

    4. In the "Check for newer versions of stored pages" list, select the "Automatically" option. 5. Save your entry by clicking the "OK" button. Logging on using the Web browser Figure 4-1 Logon page SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 40 If an incorrect password is entered, entries are blocked for a short time. The more often an incorrect password is entered, the longer entries are blocked. After a maximum number of failed attempts, the user or the client IP address is blocked for a certain time. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 41: Simulation Of The Leds

    LED. In the simulation there is a separate LED for each. There is also one common LED on the device for the "Redundancy manager" and "Standby" functions. In the WBM, these functions are simulated by two individual LEDs. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 42: Operator Activities

    ● Support If you click this menu command, an Internet connection to the support pages of SIEMENS AG is established. This is only possible when the PC supports an Internet connection. ● Logout If you click this menu command, you will log out from the WBM of the IE switch.
  • Page 43: Command Line Interface

    Tab key. The Command Line Interface then displays a command starting with the letters you typed in. If the command displayed is not the command you require, press the Tab key again to display the next command. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 44 You enter either E or D. ● If a numeric value is required as a mandatory parameter, you can also specify a range of values: Example: <0 ... 255> Enter a value between 0 and 255. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 45 Displays the commands available in the menu. Administrator and User exit Closes the CLI session. Administrator and User restart Restarts the IE switch Administrator only Info Displays information on the current menu item. Administrator and User SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 46 Configuration using WBM and CLI 4.2 Command Line Interface SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 47: Menus In The Wbm

    You can change the following entries: ● System Contact ● System Location ● System Name Figure 5-1 System Configuration System up time The system up time displays the operating time of the device since the last restart. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 48 System Configuration - CLI\SYSTEM> Command Description Comment info Shows the current system information. name [sysName] Sets the "sysName" variable. Administrator only contact [sysContact] Sets the "sysContact" variable. Administrator only location [sysLocation] Sets the "sysLocation" variable. Administrator only SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 49: I&M

    Here, you can see the individual parameters for Identification & Maintenance. I&M 1 Function tag Here, you can enter the function tag (plant designation). Location tag Here, you can enter the location tag (location identifier). SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 50: Restart & Defaults

    Restart & Defaults System Restart & Defaults In this screen, there is a button with which you can restart the device and various options for resetting to the device defaults. Figure 5-3 Restart and Defaults SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 51 System Restart & Defaults - CLI\SYSTEM\RESTARTS> Command Description Comment memreset Restores the factory defaults. The protected settings are retained. Administrator only defaults Restores the factory defaults. The protected settings are also Administrator only reset. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 52: Save & Load Http

    Name and possibly also folder path of the configuration file that you want to load on the IE Switch X-200 or where you want to store the current configuration information. Note When a configuration file is downloaded, the device type is not checked. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 53 Name of the file that contains the private key for SSL. SSL Certificate File Name of the file that contains the certificate for SSL. Private MIB File Here, you can save the private MIB of the IE switch X-200 in a file. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 54: Save & Load Tftp

    System Save & Load TFTP menu. Figure 5-5 System Save and Load via TFTP TFTP Server IP Address The IP address of the TFTP server with which you want to exchange data. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 55 X-200IRT V4.5 X201-3P IRT PRO at least X-200IRT V4.1 XF204IRT at least X-200IRT V3.1 X202-2P IRT PRO X204IRT PRO at least X-200IRT V2.1 X200-4P IRT X201-3P IRT X202-2P IRT at least X-200 V4.5 X208PRO SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 56 Loads the private SSL key from a file. Administrator only. ctname Specifies the name of the file (maximum 255 char- Administrator only acters) that contains the SSL certificate. ctload Loads the SSL certificate from a file. Administrator only SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 57: Version Numbers

    Hardware Revision Displays the version of the device. MAC Address Displays the MAC address of the device. MLFB Number Displays the order number of the device. Serial number Displays the serial number of the device. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 58 System Information - CLI\> Command Description Comment info Displays the MAC address, MLFB and serial number Table 5- 6 System Configuration - CLI\SYSTEM> Command Description Comment versions Shows versions of firmware, hardware and boot software. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 59: Passwords

    • For the user: user. Figure 5-7 System Passwords Table 5- 7 System Passwords - CLI\SYSTEM> Command Description Comment password <admin | user> Sets a new password for the user or adminis- Administrator only <password> trator. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 60: Select/Set Button

    Here, you decide whether the redundancy manager can be switched on and off by pressing the SET button. Set Fault Mask Here, you decide whether the information of the "Fault Mask" is used when the SET button is pressed. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 61 [E|D] Enables/disables the "Restore Factory Defaults" button Administrator only function. rm [E|D] Enables/disables the "Enable/Disable Redundancy Man- Administrator only ager" button function. faultmsk [E|D] Enables/disables the "Set Fault Mask" button function. Administrator only SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 62: Event Log

    Note that events occurring in quick succession are not always displayed in the causal sequence. Figure 5-9 System Event Log Table Restart Specifies the device restart after which the relevant event occurred. Sys. Up Time Shows the operating time of the device since the last restart. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 63 Indicates or erases expired events in memory. Administrator only eventmax [Max count] Specifies the maximum number of events in the log Administrator only table. A maximum of 10 to 400 entries can be set. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 64: C-Plug

    No C-PLUG or C-PLUG inserted but invalid or incompatible content. This status is also displayed if the C-PLUG was formatted during operation. ● NOT ACCEPTED, HEADER CRC ERROR A C-PLUG with bad content is inserted. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 65 During ongoing operation, changes to the configuration data are stored only on the C-PLUG. If you remove the C-PLUG later, the configuration stored internally on the basic device becomes valid again. This restores the configuration status prior to inserting the C-PLUG. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 66 Command Line Interface. By entering the useplug D command, you can change the de- vice to operate in the mode without C-PLUG. clear Erases the data on the C-PLUG. Administrator only SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 67: The X-200 Menu

    Figure 5-11 Status Power Line 1 / Power Line 2 ● up Power supply 1 or 2 is applied. ● down Power supply 1 or 2 is not applied or is below the permitted voltage. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 68 No Fault The switch has not detected any errors. The signaling contacts do not respond and the error LED does not light up. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 69: Fault Mask

    Fault Mask The settings on this page allow you to monitor the link status and the redundant power supply. Values are also displayed here that were set with the button configuration. Figure 5-12 Fault Mask SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 70 Note Since according to the factory default, neither the monitoring of the ports nor the monitoring of the power supply are activated, none of the check boxes are selected when the device ships. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 71: Ring

    If an HRP ring is configured in which a linear bus is set up in which a device is set to HRP manager and the other devices have the setting "Automatic Redundancy Detection", the error message "other RM in ring" is output. This disappears after connecting the linear bus to form a ring. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 72: Scalance X

    If no HRP manager is found, all devices with the "Automatic Redundancy Detection" or "MRP Auto Manager (Auto)/Client" setting negotiate among themselves to establish which device adopts the role of MRP manager. The other devices automatically set themselves to "MRP Client" role. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 73 "MRP Client", this device automatically adopts the role of MRP manager. Select the "MRP Client" role if you want to operate the device along with components that do not originate from Siemens in the ring. ● MRP Manager (Auto)/Client Devices with the setting "Automatic Redundancy Detection"...
  • Page 74 "Redundancy Manager": Cannot disable "Redundancy" if "Standby Manager" is enabled. Note When the devices ship, the default ring ports are set, see Appendix Default ring ports (Page 177). SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 75 Specifies the two ring ports in the range n-m. Administrator only clear Resets all redundancy counters to the original set- Administrator only ting. redund [E | D] Enables / disables ring redundancy. Administrator only SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 76: Standby

    Ethernet connection (standby port of the master) to another Ethernet connection (standby port of the slave). You will find further information on Ethernet cabling and the topological positioning of master and slave in the SCALANCE X-200 operating instructions in the section "Network topologies and media redundancy". Note •...
  • Page 77 Here, enter the name for the standby connection. This must be identical to the name entered on the standby partner. You can select any name to suit your purposes, however, you can only use the name for one pair of devices in the entire network. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 78 Specifies the name of the standby connection. Administrator only clear Resets all counters to the original setting. Administrator only standby [E|D] Enables/disables the standby manager. Administrator only force [E|D] Enables/disables the device as standby master. Administrator only SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 79: Procedure For Redundant Linking Of Rings

    5. Select the "Enable Standby Manager" option both on the master and on the slave. 6. Confirm the configuration by clicking on the "Set Values" button for the master and slave. 7. Now, you can plug in the redundant Ethernet connection. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 80: The Agent Menu

    X-200 IE switches or whether the IP address will be obtained dynamically. You can also enable options for accessing X-200 IE switches, for example TELNET. Figure 5-15 Agent Configuration SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 81 The IP address of the X-200 IE switch. If you make a change here, the WBM loses the connection to the X-200 IE switch. Enter the new address in the Internet browser to reestablish the connection. Subnet Mask Here, you enter the subnet mask of the X-200 IE switch. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 82 [M | N | C | D] Specifies the DHCP parameters: Administrator only - M MAC address - N system name - C client ID - D PNIO device name clientid [client ID] Specifies the DHCP client ID. Administrator only SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 83: Ping

    Enter the IP address of the network device you want to ping to test whether it can be reached. Repeat Here, enter the number of data packets to be sent. Ping Click this button to start sending the data packets. Ping Output This box shows the output of the ping function. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 84: Snmp Config

    Displays the user name for write access to SNMP variables. Here, changes can only be made, when write protection (SNMP read only) has been disabled. Traps Here, you can enable or disable the sending of SNMP traps. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 85 Enables / disables SNMPv1 read only mode. Administrator only getcomm [string] Specifies the Read Community string. Administrator only setcomm [string] Specifies the Write Community string. Administrator only traps [E | D] Enables / disables SNMPv1 traps. Administrator only. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 86: Snmp Trap Config

    Here, you enter the addresses of the stations to which the IE Switch X-200 will send traps. Enable Trap Click on the check box next to the IP addresses to enable the sending of traps to the corresponding stations. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 87: Snmp Groups

    On this page, you create or delete user groups for device access using SNMPv3. You can decide whether or not members of a group need to authenticate themselves, whether they communicate with encryption and whether they have read and write permissions. Figure 5-19 SNMP Configuration Groups SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 88 <index> Deletes an SNMPv3 group. The index of the group Administrator only to be deleted must be obtained with the "Info" command. clearall Deletes all the SNMPv3 groups that have been Administrator only created. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 89: Snmp Groups New Entry

    The members of the group need to authenticate themselves for SNMP access to the IE Switch X-200 but nevertheless communicate without encryption. Auth/Priv The members of the group need to authenticate themselves and communicate via an encrypted SNMP connection. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 90: Snmp Config Users

    When you create a new user, you need to assign this user to a group. You also need to set the required passwords and the authentication algorithm. The factory setting is made so that the password corresponds to the relevant user name. Figure 5-21 Agent SNMP Config Users screen SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 91 <index> Deletes an SNMPv3 user. The index of the Administrator only user to be deleted must be obtained with the "Info" command. clearall Deletes all SNMPv3 users that have been Administrator only created. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 92: Snmp Users New Entry

    Here, you enter the password with which the user you are creating will log on with the IE switch for SNMPv3 communication. Privacy Password/Password Confirmation Here, you specify the password that the user will use for encryption of SNMPv3 communication. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 93: Agent Timeout Configuration

    Permitted values for the WBM timeout: 0 to 999 minutes 0 means: There is no automatic logout. CLI (TELNET, SSH, Serial) [sec] Set the CLI timeout. Permitted values for the CLI timeout: 60 to 600 seconds 0 means: There is no automatic logout. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 94: Event Config

    The following options are available: ● The IE Switch X-200 sends an e-mail. ● The IE Switch X-200 triggers an SNMP trap. ● The IE Switch X-200IRT saves the relevant event in the event table. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 95 1 or line 2. Fault State Change The fault status has changed. The fault status can relate to the activated port monitoring, the response of the signaling contact or the power supply monitoring. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 96 Select this check box if you want to close the signaling contact. Note The setting of the "Close Signaling Contact" check box is only effective if the "aligned" setting was selected in the "Signaling Contact Control" drop-down list. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 97 • Trap • Entry in the log table • Example: If you only want to send an e-mail when there is a Link Change, enter the fol- lowing command: setec LC E D D SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 98: E-Mail Config

    Here, you enter the E-mail address to which the IE Switch X-200 sends an E-mail if a fault occurs. SMTP Server IP Address Here, you enter the IP address of the SMTP server over which the E-mail is sent. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 99 Specifies the address to which an IE switch Administrator only sends an E-mail. This address can be up to a maximum of 50 characters long. testmail <test E-mail com- Sends an E-mail for testing. Administrator only ment> SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 100: Time Config

    Note Time-of-day synchronization SCALANCE X-200 IE switches do not have a quartz clock for their internal time of day. This means that the speed of the clock can vary by more than 1 second a day between two different devices.
  • Page 101 Once the system time has been adopted the first time from the time server, it is updated cyclically with renewed polls to the time server. Here, you specify how often the updates take place. Range of values: 10 - 100000 SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 102 Select how the frames for time-of-day synchronization will be signed. You have the two options: MD5 and SHA. Key ID Enter the key ID to be used for signing. Permitted values for the key ID: 1-65534. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 103 [P | L | S | N | M] Specifies how the time is set: Administrator only - P SNTP Poll - L SNTP Listen - S Siemens - N NTP - M Manual. time [date] [time] If no parameters are set, this command shows the Administrator only time.
  • Page 104: Daylight Saving Time

    The table shows you an overview of the existing entries for the daylight saving time changeover. As soon as the end date of an entry is exceeded, if a rule is defined, the data for the next changeover is displayed. With fixed entries, the row is deleted. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 105 ● Date You can define a fixed date for the daylight saving time changeover. This setting is suitable for regions in which there is no rule governing the daylight saving time changeover. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 106 End date Enter the following values for the end of daylight saving time: ● Week of the month You can select the 1st to 5th or the last week of the month. ● Weekday SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 107 Enter the year for the daylight saving time changeover. Start date Enter the following values for the start of daylight saving time: ● Month ● Day ● Time of day in hours End date SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 108 2010 040102 100103 following form: mmddhh • delete <index> Deletes an entry. The index of the entry to be Administrator only deleted must be obtained with the "info" com- mand. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 109: Pnio Config

    PROFINET IO controller cannot be configured on the IE switch. PNIO Device Name Here, you enter the PROFINET IO device name (Name of Station) according to the configuration in HW Config. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 110 5.3 The Agent menu Syntax of the Command Line Interface Table 5- 26 PNIO Configuration - CLI\AGENT\PNIOCONF> Command Description Comment info Shows the current PROFINET IO configuration devname [string] Sets the PROFINET IO device name. Administrator only. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 111: Management Acl

    Shows the number of the access rule. If you define a new access rule, a new row with a unique number is created. IP Address Shows the IP address to which the access rule applies. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 112 Enter the subnet mask to which the access rule applies. The subnet mask 255.255.255.255 is for a specific IP address. The subnet mask 0.0.0.0 applies to all subnets. If you want to allow a specific subnet, for example a C subnet, enter 255.255.255.0. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 113 Specifies the ports via which the device may be Administrator only Mask] <E|D> [port] accessed. services [IP address] [Subnet Specifies the protocols that can be used to Administrator only Mask] <E|D> [service] access the device. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 114: The Switch Menu

    Mirroring Enabled Clicking this check box enables or disables the mirroring function. Mirrored Port Under mirrored port, enter the port to be monitored. Monitor Port Under monitor port, enter the port to be monitored. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 115 (mirrored port). Non-cyclic frames mean that PROFINET communication is not involved and, in this case therefore, both sent and received packets are shown at the mirror port (monitor port). SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 116 Enables/disables the oversize mode function Administrator only aging [E|D| Aging Enables/disables whether or not the aging time of the switch Administrator only time] can be set. *) Only relevant for devices without the IRT function. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 117: Ports

    The following port types are available with the IE Switch X-200 modules: ● TP 10 TX ● TP 100 TX ● FO 100 FX Mode Shows transmission rate (10 or 100 Mbps) and the transmission mode (full duplex (FD) or half duplex (HD)). SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 118 If an IE switch port is set permanently to full duplex, the connected partner device must also be set to full duplex. If the autonegotiation function is disabled, the MDI/MDI-X autocrossover function is also inactive. This means it may be necessary to use a crossover cable. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 119: Fmp

    ● To be able to use the Fiber Monitoring (FM) function, enable LLDP. The FM information is appended to the LLDP packets. ● You can only use Fiber Monitoring with transceivers capable of diagnostics. Devices and modules with transceivers capable of diagnostics have the supplement "FM" in the name. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 120 In "Agent > Event Configuration", you can specify how the IE switch indicates the event. In "X-200 > Fault Mask", you can also specify whether or not an error should be signaled. Figure 5-36 Fiber Monitoring Protocol SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 121 Enable or disable FM. Rx Power State ● disabled FM is disabled. ● ok The value for the received power of the optical link is OK. ● maintenance required Check the link. An event is triggered. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 122 If no diagnostics information has been received for 5 cycles, the connection counts as being interrupted. A cycle lasts 5 seconds. Power loss [dB] Shows the current value of the power loss. The value can have a tolerance of +/- 3 dB. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 123 Enables / disables FM for the specified port. Administrator only Table 5- 32 Fiber Monitoring - CLI\SWITCH\FM> Command Description Comment info Shows general information about the transceivers, for example model, serial number and current values, e.g. received and transmit power. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 124 The horizontal axis shows the time since the IE switch started up relative to the current time of day and the current date. Date and time information are adopted from the PC on which the Web browser in use is running. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 125 "Rx Power Maintenance required". ● Orange If the received power enters the orange range, urgent maintenance is necessary. The limit value between the yellow and orange area corresponds to the setting for "Rx Power Maintenance demanded". SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 126 The horizontal axis shows the time since the IE switch started up relative to the current time of day and the current date. Date and time information are adopted from the PC on which the Web browser in use is running. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 127 Maintenance required". ● Orange If the power loss enters the orange range, urgent maintenance is necessary. The limit value between the yellow and orange area corresponds to the setting for "Power loss Maintenance demanded". SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 128: Cable Tester

    Select the port to which the cable you are testing is connected. Run Test This button activates the error diagnostics. Pair Displays the pair of wires in the cable. Pairs 4-5 and 7-8 are not used. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 129: Pof

    (POF) is used. If polymer cladded fiber (PCF) is used, diagnostics is not possible. The following X-200 IE switches use Plastic Optical Fiber (POF)as the transmission medium: ● X200-4P IRT ● X201-3P IRT ● X201-3P IRT PRO ● X202-2P IRT ● X202-2P IRT PRO SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 130 The longer the cable being used, the lower the link power margin available. The diagnostics page shown below appears if you click on one of the displayed ports. It displays information on the available link power margin over time. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 131 The horizontal axis shows the time since the IE switch started up relative to the current time of day and the current date. Date and time information are adopted from the PC on which the Web browser in use is running. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 132: Fdb

    FO LED of the relevant port lights up. 5.4.6 Switch Forwarding Database This page shows which MAC addresses are currently reachable via which port. The FDB is renewed when the aging time elapses. Figure 5-42 Switch Forwarding Database SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 133 ● dcp The entry was created for DCP. In the factory settings, DCP is enabled on all ports. ● si-time The entry was created for SIMATIC Time. In the factory settings, SIMATIC Time is disabled. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 134 SCALANCE X-200IRT IE switches can learn up to 4000 Ethernet addresses, the other SCALANCE X-200 IE switches up to 8000 Ethernet addresses. The entry of a learned Ethernet address in the address table is made by the storage system which may reduce the actual number of addresses that can be learned.
  • Page 135: Arp Table

    This dialog shows which MAC address is assigned to which IP address. Figure 5-43 Switch ARP Table Syntax of the Command Line Interface Table 5- 35 Switch ARP Table - CLI\SWITCH> Command Description Comment Displays the ARP table. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 136: Lldp

    With all other X-200 IE switches, MAC addresses are used as the sender address for LLDP frames that are both device and port-specific. The MAC address for a specific port is formed by adding the index of this port to the MAC address of the X-200 IE switch. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 137 Port sends and receives LLDP frames. LLDP frames are neither sent nor received. (not with X-200IRT IE switches) LLDP frames are sent but not received. LLDP frames are received but not sent. (not with X-200IRT IE switches) SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 138: Dcp

    To allow the logical structuring of networks, the sending of DCP frames can be enabled or disabled port-oriented on an X-200 IE switch. Note The sending of DCP frames can be disabled in STEP 7 using the "End of detection of accessible nodes" function. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 139 If DCP is turned off, it may not be possible to configure all switches with the PST tool. Figure 5-45 DCP switch The following settings can be made for the displayed ports: Symbol Meaning Port sends and receives DCP frames. DCP frames are received but not sent. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 140: Loop Detection Config

    If the sent frames are received again at the same port, there is a "Remote Loop" involving other network components. Note Note that loop detection is only possible at ports that were not configured as ring ports. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 141 Menus in the WBM 5.4 The Switch menu Figure 5-46 Loop Detection Configuration SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 142 ● "Local Loop Reaction" drop-down list Here, you can activate or deactivate a port if a local loop is detected. ● "State" display box Shows the status of the loop detection for the corresponding port. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 143 Specifies the reaction to a local loop. Administrator only remote <port> [N | D] Specifies the reaction to a remote loop. Administrator only reset <port> Reactivates the port if it was deactivated due to a Administrator only detected loop. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 144: The Statistics Menu

    This information provides you with an overview of the data traffic and any problems on the network. Figure 5-47 Statistics Throughput Octets In Displays the number of received bytes. Octets Out Displays the number of sent bytes. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 145 Shows statistical information on sent and received frames. types Displays information on the type of the sent and received frames. sizes Displays information on the length of the sent and received frames. errors Displays information on bad sent and received frames. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 146: Packet Size

    Displays the number of packets with a length of 128-255 bytes. 256-511 Displays the number of packets with a length of 256-511 bytes. 512-1023 Displays the number of packets with a length of 512-1023 bytes. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 147 Displays the number of packets with a length of 1024-1518 bytes. Figure 5-49 Statistics Packet Size Graphic Syntax of the Command Line Interface Table 5- 40 Statistic Packet Size - CLI\INFORM> Command Description Comment sizes Shows statistical information broken down according to frame length. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 148: Packet Type

    Statistics Packet Type Unicast Displays the number of packets to the unicast recipient address. Multicast Displays the number of packets to the multicast recipient address. Broadcast Displays the number of packets to the broadcast recipient address. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 149 5.5 the Statistics menu Figure 5-51 Statistics Packet Type Graphic Syntax of the Command Line Interface Table 5- 41 Statistic Packet Type - CLI\INFORM> Command Description Comment types Shows statistical information broken down according to frame type. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 150: Packet Error

    Packets too long with valid checksum. Fragmented (Only with devices without the IRT function.) 
 P ackets with a length less than 64 bytes and a bad CRC checksum. Jabbers Packets too long without valid checksum. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 151 If the frame involved is a frame with a length of 64 bytes, the counter for undersize errors is also incremented due to the shortening of the frame Syntax of the Command Line Interface Table 5- 42 Statistic Packet Error - CLI\INFORM> Command Description Comment errors Displays statistical information on received errors. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 152 Menus in the WBM 5.5 the Statistics menu SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 153: Configuration Via Snmp

    TCP/IP networks to be displayed. With the additional monitoring of this data, device failures can be detected and localized quickly. This increases operational safety and improves plant availability. With STEor alternatively NCM PC, you configure which devices are monitored by the SNMP OPC server. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 154 To access the private MIB file of an IE switch, follow the steps below: 1. Open Web Based Management. 2. Select the System -> Save & Load HTTP menu item. 3. Click the "Save Private MIB" button. 4. Follow the instructions in the window that opens. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 155: Connection To Profinet Io

    Connection to PROFINET IO connection via STEP 7 The SCALANCE X-200 IE switches are also suitable for use in a network with PROFINET IO. The devices must be linked into PROFINET IO using STEP 7. How this connection is achieved is not covered in these operating instructions but is explained in the STEP 7 help.
  • Page 156: Configuring The Interrupts In Step 7

    The configuration of the "C-PLUG error" and "Redundant power supply" interrupts of the SCALANCE X-200 IE switches is a special feature among the SIMATIC net devices. For this reason, you will not find any information in the STEP 7 help relating to configuration of these two interrupts.
  • Page 157: Mrp Configuration In Step 7

    If you want to configure a single MRP ring, leave the factory setting "mrpdomain 1" in the "Domain" drop-down list. All devices configured in a ring with MRP must belong to the same redundancy domain. A device cannot belong to more than one redundancy domain. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 158 Role The choice of role depends on the following use cases. ● You want to use MRP in a topology with one ring only with Siemens devices and without monitoring diagnostic interrupts: Assign all devices to the "mrpdomain-1" domain and the role "Manager (Auto)".
  • Page 159 If you enable this option, existing redundancy settings from WBM, CLI or SNMP, are retained and are not overwritten. The parameters in the "MRP configuration" box are then reset and grayed out. The entries then have no meaning. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 160 MRP configuration in STEP 7. Information on the ring ports You will find a list of the default ring ports of the individual device variants in the Appendix Default ring ports (Page 177). SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 161: Configuring The Topology In Step 7

    "Object Properties" entry from the context menu. 3. Then select the "Topology" tab. Figure 7-1 STEP 7 HW Config dialog box, "Topology" tab SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 162 – "Any partner" Select this setting, if you do not want the topology be monitored. The is the default setting. ● Changing partner ports Here, select all ports to be monitored when ports alternate. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 163: Configuring Hrp

    If incompatible firmware is downloaded to the device, it will no longer be possible to operate the device. In this case, compatible firmware will have to be loaded again with the boot loader. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 164 X-200IRT V3.1 X202-2P IRT PRO X204IRT PRO at least X-200IRT V2.1 X200-4P IRT X201-3P IRT X202-2P IRT at least X-200 V4.5 X208PRO at least X-200 V4.3 X204-2TS at least X-200 V4.1 XF204 XF204-2 XF206-1 XF208 SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 165: Structure Of The Data Records

    Red_power Bits 2...31 Bit 1 Bit 0 0: No C-PLUG monitoring. 0: No monitoring of the redundant power supply. 1: Missing or incorrect C-PLUG generates 1: Monitoring of the redundant power sup- alarm. ply. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 166: Data Record 5

    0: not redundant 1: Fault line active 0: C-PLUG inserted 1: redundant and ok 1:C-PLUG not inserted 2: C-PLUG inserted but not ok (incorrect type) 3: C-PLUG inserted but not ok (checksum error) SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 167: Data Record 0X802A

    Constant = 0x020F BlockLength Constant, describes the length of the data record without the "BlockType" and "BlockLength" fields. BlockVersionHigh Constant = 1, designates the major version. BlockVersionLow Constant = 0, designates the minor version. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 168: Scalance X

    Length of the "PeerChassisID" field in bytes. PeerChassisID ID of the neighboring device. LineDelay LineDelay.FormatIndicator = 0 Value (hexadecimal) Meaning 0x00000000 Line delay and cable delay unknown. 0x00000001 – 0x7FFFFFFF Line delay in nanoseconds. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 169 0x0017 1000BASELXHD 0x0018 1000BASELXFD 0x0019 1000BASESXHD 0x001A 1000BASESXFD 0x001B – 0x001C Reserved 0x001D 1000BASETHD 0x001E 1000BASETFD 0x001F 10GigBASEFX 0x0020 – 0x002D Reserved 0x002E 100BASELX10 0x002F – 0x0035 Reserved 0x0036 100BASEPXFD 0x0037 – 0xFFFF Reserved SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 170 Reserved MediaType Value (hexadecimal) Meaning 0x00 Unknown 0x01 Copper cable 0x02 Fiber-optic cable 0x00 Wireless communication 0x04 – 0xFFFFFFFF Reserved Note You will find further information on the IEC data record in IEC 61158. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 171: Downloading Firmware

    Loading with the boot loader if a fault occurs You will find more detailed information on updating the firmware if a fault occurs in the section Loading firmware using the boot loader (Page 172). SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 172: Loading Firmware Using The Boot Loader

    2. Send a firmware file to the X-200 IE switch using FTP. You can use any FTP client to do this. Use the following connection settings for FTP access: – User name: siemens – Password: siemens – Transmission mode: Binary Once it receives the file, the device updates the firmware and restarts automatically.
  • Page 173: A

    2. Datalink/subnet (for example bridges, switches) 3. Internet (for example IP gateways, routers) 4. End to end (for example IP hosts) 5. - 6. - 7. Applications (for example e-mail servers), data type: 32-bit integer SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 174 Read only The value ethernet-csmacd(6) or optical(65) is entered for SCALANCE X-200. ifSpeed Read only Data transfer rate of the Ethernet port in bits per second. With SCALANCE X-200 devices, this is either 10 Mbps or 100 Mbps. ifOperStatus Read only The current operating status of the Ethernet port.
  • Page 175: Important Private Mib Variables

    The serial number of the product. snMacAddressBase Read only The MAC address of the X-200 IE switch. snSwVersion Read only The software version of the system. snInfoMLFB Read only The MLFB number of the device. SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 176 • SCALANCE X202-2P IRT PRO • SnX200RmMode Read only The redundancy manager mode 1: The X-200 IE switch is a redundancy manager. • 2: The X-200 IE switch is not a redundancy manager. • SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 177: Default Ring Ports

    Default ring ports Default ring ports of the IE switches SCALANCE X-200 SCALANCE X200 and SCALANCE XF200 Product name: Default ring ports: X208 P1 and P2 X208PRO P1 and P2 X216 P1 and P2 X224 P1 and P2 X204-2 P5 and P6...
  • Page 178 Default ring ports SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 179: Index

    HRP, 24 Selection Tool, 4 SIMATIC NET glossary, 7 SIMATIC NET Selection Tool, 4 IP address, 35 SNMP Configuration options, 35 supported versions, 153 Isochronous Real-time Ethernet, 29 Star topology, 14 STEP 7, 35 SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...
  • Page 180 Index Subnet mask, 34 Support, 42 Syntax CLI, 44 System manual, 4 SCALANCE X-200 Configuration Manual, 03/2015, C79000-G8976-C285-06...

Table of Contents