Siemens SIMATIC NET SCALANCE X-200RNA Operating Instructions Manual page 119

Industrial ethernet switches
Hide thumbs Also See for SIMATIC NET SCALANCE X-200RNA:
Table of Contents

Advertisement

Figure 9-25
Agent SNMP Configuration
• "SNMPv1/v2c/v3"
Here, you enable / disable SNMPv1/v2c/v3 for a SCALANCE X-200RNA.
• "SNMPv3 Only"
Here, you enable / disable SNMPv3 Only for a SCALANCE X-200RNA.
• "Read Only"
When this check box is selected, you can only read SNMP variables with SNMPv1/v2c.
• "Read Community String"
Here, you enter the read community string (maximum of 63 characters) for the SNMP
protocol.
• "Read/Write Community String"
Here, you enter the write community string (maximum of 63 characters) for the SNMP
protocol.
• "Traps"
This enables / disables the sending of SNMPv1/v2c traps.
SCALANCE X-200RNA
Operating Instructions, 04/2022, C79000-G8976-C342-07
Functional description and configuration using Web Based Management
9.9 The "Agent" menu
119

Advertisement

Table of Contents
loading