Agent Time Configuration - Siemens SIMATIC NET SCALANCE X-200RNA Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SIMATIC NET SCALANCE X-200RNA:
Table of Contents

Advertisement

9.9.12

Agent Time Configuration

Time-of-day synchronization in the network
SNTP (Simple Network Time Protocol) is used for synchronizing the time in the network. The
appropriate frames are sent by an SNTP server in the network. A SCALANCE X-200RNA logs on
as client with this server as recipient of time-of-day frames.
Figure 9-37
Agent Time Configuration
• "System Time"
This box displays the current system time. If no time-of-day synchronization was possible, the
box displays "Date/time not set".
• You can also set the date and time manually, the required input format is MM/DD/YYYY
HH:MM:SS. In this case, the text box displays the data and time along with the suffix (m). If
the system time was set as a result of synchronization with a server, the suffix is (p).
• "Time Synchronization"
This box is read-only and shows when the last time-of-day synchronization took place.
SCALANCE X-200RNA
Operating Instructions, 04/2022, C79000-G8976-C342-07
Functional description and configuration using Web Based Management
9.9 The "Agent" menu
133