Teledyne CP Series User Manual page 68

Table of Contents

Advertisement

User Manual
CP Series
Version 3.1 – June 2020
Command description
Command syntax
Description
Retrieve current status of
?ST
PowerBox/Generator
?RC
Ask the rating chart
Reply from PowerBox
!ST<WW>,<XXXX>,<Y>,<ZZZ>...
!RC<AAA>,<BBB>,<CCC>,
<DDD>,<EEE>,<FFF>,<GGGG>
Fields description
Field name
Description
Status code:
0: Connecting
1: No generator
2: Ready to start
3: Error state
4: Preheating required
5: Reserved for future use
<WW>
6: Prewarning in progress
7: Ramp in progress
8: Shot in progress
9: End of shot
10: Wait in progress (between cycles)
11: Shot restart?
12: Prompt message
<XXXX>
Remaining time (prewarning, shot, wait)
<Y>
Number of errors
<ZZZ>
Error codes, separated by commas
<AAA>
<BBB>
<CCC>
<DDD>
<EEE>
kV min @ mA max
<FFF>
mA max @ kV min
<GGGG>
Power max
Min mA
Max mA
kV min
kV max
units
N.A.
s
N.A.
N.A.
mA/10
mA/10
kV
kV
kV
mA/10
W