The maximum total power consumption for the 24V powered lamps is 15W.
The maximum total switched current of the relays is 2A.
The wire cut (pin M) needs to be connected to ground (pin A) to enable the PowerBox to detect if a cable
is connected to the interlock connection. The external 24Vdc (pin G) is only enabled when the wire cut is
connected to ground.
A 24 Vdc is provided by the PowerBox to power external flashing lights and siren.
The input contacts Door 1, 2, 3, Water and Oil (pin B to pin F) are fully configurable input signals which can
be used as a door contact or other relative safety interlock inputs. The Water and Oil input are foreseen for
future development when water or oil cooling elements are developed for the Site-X CP range. For now,
they can be treated as auxiliary door contacts.
Please refer to the PowerBox's 'Configure interlock' chapter for more information on how to configure the
inputs.
Lamp 1 to 4 are 4 fully configurable output contacts which can be used in combination with the 24Vdc
provided by the PowerBox for warning lamps, sirens or any other 24V output or warning device provided
the max power consumption is respected.
The maximum total power consumption for all 4 ports combined is 15 Watt.
The respective port is internally connected to ground when the output is activated. Each port also has a
consumption current detection to detect lamp failure. The alarm for this is configurable per port.
Please refer to the PowerBox's 'Configure interlock' chapter for more information on how to configure the
outputs.
Relays 1 to 4 provide 4 programmable output ports with a maximum switching voltage rating of 240Vac or
30Vdc. Each relay is protected internally by a 2 Amp resettable fuse. Also, the common line is protected
by a 2A resettable fuse. The total current consumption for all ports together can thus not exceed 2A.
Please refer to the PowerBox's 'Configure interlock' chapter for more information on how to configure the
relays.