List of Log Messages

Log Messages on the Camera

The list of log messages displayed in [System] > [Maintenance] > [Log] > [View Logs] on the Settings Page (P. 84).
Log messages are classified into the following types.
Category
Level
crit
Error
err
Error
warning
Warning
notice
Warning
info
Information
Note
If no content is recorded in a log for approximately two hours, "-- MARK --" will be recorded in the message area.

Error Log

System Error
S303 Error on saving settings [err]
Description
Can't update files of system settings
(S303)
Meaning
An error generated while the system
was saving a setting, Can't update
system settings.
Countermeasure
If the error is detected after rebooting,
initialize to the factory default settings. If
the problem persists, contact the
dealer.
S320 PAN/TILT operation error [err]
Description
%1 error occurred. [%2] (S320)
%1
PAN | TILT
%2
Error details
Meaning
An error occurred during operation or
stopping of PAN/TILT.
Countermeasure
Check if there is anything that interferes
with the PAN/TILT operation, such as the
contact of the camera head with
something. After resolving, execute [Pan/
Tilt Initialization] (P. 80). If it is still not
resolved, it may be a camera failure, so
contact the dealer.
Code
4xx
Software-level failure (Task operations will stop)
3xx
Operational error (Operations will continue)
2xx
Non-operational error
1xx
Error external to the system
0xx
Information on normal operation
Fault level
S330 Broken Fan [err]
Description
Meaning
Countermeasure
S332 Fan Operation has failed [err]
Description
Meaning
Countermeasure
S350 Error in resuming from or switching to
standby [err]
Description
Meaning
Countermeasure
93
FAN does not rotate. (S330)
The fan does not rotate or a significant
decrease in speed is detected.
If the error is still detected after
rebooting, it may be a failure with the
fan, so contact the dealer.
Cannot control FAN. (S332)
IO is not available to control the fan.
If the error is still detected after
rebooting, it may be a fan failure, so
contact the dealer.
Failed to resume from standby or switch
to standby (S350)
Failed to resume from or switch to the
standby status.
If the error is still detected after
rebooting, contact the dealer.