Cascading - ATEN CM1284 User Manual

Multi-view kvmp switch
Hide thumbs Also See for CM1284:
Table of Contents

Advertisement

Cascading

To centrally control up to 4 CM1164A units (16 computers/video sources),
cascade 4 additional CM1164A units to another CM1164A. As many as 16
computers/video source devices can be controlled from a single CM1164A
console in a complete cascade installation.
To set up a cascade installation, make sure that the power to all devices has
been turned off, and then do the following:
1. Connect the console ports of a secondary CM1164A to any of the DVI
KVM Ports on the primary CM1164A using the provided KVM cables.
2. To cascade another CM1164A, repeat step 1.
3. Connect the secondary CM1164A units with computers/video sources. For
detailed steps, see Single Station Installation, page 15.
4. Connect the primary CM1164A with a USB keyboard and a USB mouse.
5. Power up the installed CM1164A units. After all the stations are up, power
on the connected computers/video source devices.
Note: Make sure the computers and devices that the CM1164A connects
to are also properly grounded.
6. Change the installation setting from Daisy Chain to Cascade in the OSD
Menu (Advanced > Expansion).
7. Each secondary CM1164A unit is recognized as an input source (port 1 ~
4) to the primary CM1164A. To only display the sources of a particular
secondary CM1164A, use any of the following methods:
 Press the corresponding front-panel port pushbutton
 Press the corresponding port button on the IR remote control
Chapter 2. Hardware Setup