Manifolds; Function Manifold Components - Terex SX135XCH-101 Service And Repair Manual

Table of Contents

Advertisement

Service and Repair Manual

Manifolds

8-1

Function Manifold Components

The function manifold is mounted next to the hydraulic tank on the ground control side of the machine.
Index
Description
No.
1
Solenoid valve, 3 position 4 way CC
2
Relief valve, 1750 psi / 120.7 bar
Pressure compensator valve, 150 psi /
3
10.3 bar
4
Check valve, 10 psi / 0.7 bar
5
Flow control valve, 2 way NC
Solenoid operated 3 position 4 way
6
directional valve
7
Check valve, 100 psi / 6.9 bar
8
Check valve, 10 psi / 0.7 bar
9
Check valve, 10 psi / 0.7 bar
10
Relief valve, 3200 psi / 221 bar
11
Check valve
12
Flow control valve, 2 way, NC
94
Schematic
Item
M
Primary boom extend/retract
Primary boom extend relief
Q
pressure
F
Turntable rotate
S
P
Primary boom extend/retract
H
Turntable rotate
R
Primary boom extend/retract
D
Aux 2 reverse flow
C
Aux 1 reverse flow
G
System relief
B
Function pump reverse flow
E
Turntable rotate flow control
SX™-135 XC™
December 2018
Function
115-125 ft-lbs /
Part No. 1263383GT
Torque
156-170 Nm
33-37 ft-lbs /
45-50 Nm
33-37 ft-lbs /
45-50 Nm
20 ft-lbs /
27.1 Nm
33-37 ft-lbs /
45-50 Nm
24-26 ft-lbs /
32.5-35.3 Nm
24-26 ft-lbs /
32.5-35.3 Nm
20 ft-lbs /
27.1 Nm
20 ft-lbs /
27.1 Nm
25-27 ft-lbs /
34-36 Nm
50 ft-lbs /
68 Nm
19-21 ft-lbs /
25.7-28.5 Nm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Genie sx-135xc

Table of Contents