Faults:) StoredClear-All; Faults:) Mask; Select:) Pre-Selects Menu Branch - Comtech EF Data UT-4579 Installation And Operation Manual

X-band up converter
Table of Contents

Advertisement

UT-4579 X-Band Up Converters
Front Panel Operation
Once the number of faults reaches 100, the 100
stored faults remain in memory until you execute the CLEAR-ALL command.
Press ENTER or CLEAR to return to the previous menu.
6.2.5.2.2 (FAULTS:) STOREDCLEAR-ALL
Use the   keys to select No or Yes. Press ENTER.
When you select Yes, the unit clears the faults log and returns you to the
previous menu. However, if there are faults present on the unit at this time, the
unit will re-stamp the faults and generate new log entries.

6.2.5.3 (FAULTS:) MASK

The MASK selection is disabled in redundancy systems.
Set the fault handling for the External Reference, when applicable. Use the  
keys to select Fault or Masked. Press ENTER.
6.2.6

(SELECT:) PRE-SELECTS Menu Branch

You may create (program) up to 32 operating configurations and recall them as
needed via the LOAD submenu. If your unit does not contain any pre-selects, the
screen initially appears as follows:
Clear All Stored Faults
No
Yes
Ext Ref Lock Detect:
Fault Masked
#XX LOAD PROGRAM CLEAR
No Pre-Select Programmed
6–20
MN/UT4579.IOM
th
fault displays as "ER." The
Revision 1