LBC-4000 L-Band Up/Down Converter System
Front Panel Operation
5.2.3

SELECT: Faults

FAULTS: Conv-A Conv-B
PwrSupA PwrSupB Stored
 
Use the [←][→] arrow keys to select Conv‐A, Conv‐B,  PwrSupA, PwrSupB, or RefOsc, and then 
press [ENT] to display. Otherwise, use the [←][→] arrow keys to select Stored, and then press 
[ENT] when done. Otherwise, use the [←][→] arrow keys to select Stored, and then press [ENT] 
when done. 
 
Details about these read‐only FAULTS screens are as follows: 
 
Submenu
Conv-A
Conv-B
PwrSupA
PwrSupB
 
Press [ENT] or [CLR] to return to the previous menu from any read‐only FAULTS screen.  
5.2.3.1
FAULTS

FAULTS Stored:

View
 
Use the [←][→] arrow keys to select View or Clear, and then press [ENT] when done. 
FAULTS
Stored
Fault No. 06 22:08:26
OK-IFLO_A 08/10/04
 
Use the[↑][↓] arrow keys to scroll between and view the available lists of current faults. A total 
of 100 faults can be stored in memory as they occur, and the faults are date and time stamped. 
The  stored  faults  remain  in  memory  until  a  Clear  command  is  executed.  When  the number of 
faults reaches 100, the 100
Screen Example
FAULTS Cnv-A:
ifLO=OK rfLO=OK temp=OK
FAULTS Cnv-B:
ifLO=OK rfLO=OK temp=OK
FAULTS Pwr Supply A:
12V=OK
08VT=OK 05VT=OK
FAULTS Pwr Supply B:
12VT=OK 08VT=OK 05VT=OK
Stored
Clear
View
th
 fault will display an error (
Description
For Converter Unit A or B: The selected
Up/Down Converter IDU operating states are
shown, where:
ifLO= IF Lockout
rfLO = RF Lockout
temp = Operating Temp
OK = operation is normal
FT = operation is faulted.
Where 'X' denotes Power Supply 'A' or 'B':
The 12V, 8V, and 5V operating states for the
selected power supply are shown, where:
OK = operation is normal
FT = operation is faulted.
ER
). 
5–11
Revision 4
MN/LBC4000.IOM