Stored Alarms; Tsa (Total Stored Alarms); Cas (Clear All Stored Alarms); Laa (List All Alarms) - Comtech EF Data UT-4500 Series Installation And Operation Manual

C- and ku-band up converters
Hide thumbs Also See for UT-4500 Series:
Table of Contents

Advertisement

UT-4500 Series C- and Ku-Band Up Converters
Serial Interface Operation
8.7.6

Stored Alarms

Up to 100 alarms are date- and time-stamped and stored in memory as they
occur. The alarm entry is also updated with its date/time of clearance. The entry
remains in memory until it is cleared by the CAS command.
8.7.6.1

TSA (Total Stored Alarms)

Use TSA to retrieve the total number of stored alarms and the time and date of
the most recent alarm.
Description
Retrieve Total Alarms:
Confirmation:
8.7.6.2

CAS (Clear All Stored Alarms)

Description
Clear All Alarms:
Confirmation:
8.7.6.3

LAA (List All Alarms)

Use LAA to retrieve a list of the stored alarms. This query is unavailable when
using virtual addressing mode.
Description
List All Alarms:
Confirmation:
Details
<DEV/TSA_{cr}
>DEV/TSA_TOTAL:nn{cr}
LAST:hh:mm:ss mm/dd/yy{cr}{lf}] where:
nn = 0 to 99; the 100th alarm will be ER
hh.mm.ss = time in hour:minutes:seconds
mm/dd/yy = date in month/day/year
Details
<DEV/CAA_YES{cr}
>DEV/CAA_CLEARED{cr}{lf}]
Details
<DEV/LAA_{cr}
>DEV/LAA_{cr}
xx yyyyyyyyyyy hh:mm:ss mm/dd/yy{cr}
"
"
"
xxx yyyyyyyyyyy hh:mm:ss mm/dd/yy{cr}{lf}] where:
xx
= stored fault number
yyyyyyyyyyy
= fault description
hh:mm:ss = fault time
mm/dd/yy = fault date