4250 Flow Meter
Section 1 Introduction
Table 1-1 4250 Controls, Indicators, and Connectors
CONTROLS
SETTINGS
ON/OFF
On - Off
Keypad
Momentary
Switches
INDICATORS READING
Display
Multi-function
Internal Plotter
Various
CONNECTOR TYPE
12 VDC
2-pin male M/S
Sampler
6-pin male M/S
Rain Gauge/
9-pin female M/S
YSI 600 Sonde
(Custom)
Interrogator
6-pin female M/S Provides serial data in/out and power. Can also be used with 4-20 mA Output
Modem
5-pin male M/S
(optional)
6-pin male M/S
Analog Output
(optional)
Parameter
7-pin female M/S Connects flow meter to parameter sensor: temperature, pH, or D. O. Note that
Area Velocity
9-pin custom spe-
Sensor
cial connector
Size
Weight
Material
Type
1-8
FUNCTION
Turns the flow meter on and off. Internal memory is protected with a standby
battery. See Section 2.
24-key. 4 column matrix - Program flow meter through series of keystrokes
prompted by messages on the display. Certain keys perform specific functions,
(printing reports or entering program choices into memory). Arrow keys move
through menus. Number keys enter numeric values. See Section 2.
FUNCTION
2-line, 40 characters per line, liquid crystal display (LCD.) Prompts you through
program procedure; displays total flow,. present flow rate and level. May also
display parameter readings, if sensors present.
Provides hard copy of total flow, level or flow rate variation over time; provides
sampling information and a printout of the program. Prints reports. Generates
up to 3 different linear data plots. Chart characters and plots are generated on
plain paper roll with an ink ribbon.
FUNCTION
Connects 12 VDC power to flow meter
Connects flow meter to sampler. Provides 12V flow pulse to sampler (pulse
width 78 ms). Receives sampler bottle number, composite sample, and event
mark signal.
Connects flow meter to a Isco Rain Gauge or YSI 600 Multi-Parameter Sonde.
Also provides output to High Low Alarm Relay Box.
Interface.
Connects flow meter to telephone line for remote data transmission. This con-
nector will only be present on units that have the optional modem installed.
Provides analog data output from the flow meter to external, non-Isco control
and recording devices.
you can only have temperature and one parameter (pH or D. O.) at the same
time.
Connects flow meter to area-velocity sensor. Also provides connection for inter-
nal vent tube from sensor.
Table 1-2 4250 Technical Specifications
Physical and Electrical
1
1
16" high  11
/
" wide10
2
attached).
17 lb. 4 oz. (7.8 kg)
High-impact molded polystyrene structural foam.
Self-certified NEMA 4X Enclosure.
"deep (40.6 29.2cm) (without power source
/
2