MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE
(Addendum to GFC7000E Manual PN 04584)
MODEL GFC7000EU
C O
ANALYZER
2
(Addendum to GFC7000E Manual PN 04584)

Teledyne Analytical Instruments

16830 Chestnut St.
City of Industry, Ca. 91748
TEL: 626-961-9221
FAX: 626-961-2538
TEL: 626-934-1500
E-MAIL: ai-customerservice@teledyne.com
WEB SITE: http://www.teledyne-ai.com
1
05134 Rev -

Advertisement

Table of Contents
loading

Summary of Contents for Teledyne GFC7000EU

  • Page 1: Teledyne Analytical Instruments

    MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) MODEL GFC7000EU ANALYZER (Addendum to GFC7000E Manual PN 04584) Teledyne Analytical Instruments 16830 Chestnut St. City of Industry, Ca. 91748 TEL: 626-961-9221 FAX: 626-961-2538 TEL: 626-934-1500 E-MAIL: ai-customerservice@teledyne.com WEB SITE: http://www.teledyne-ai.com...
  • Page 2: Specifications

    (Addendum to GFC7000E Manual PN 04584) OVERVIEW The model GFC7000EU is a close derivative of the Model GFC7000E CO Analyzer. The optical bench is longer (14 m), making the instrument more sensitive at low CO levels. The instrument has a user selectable full scale range of 0-100 PPB to 0-100 PPM of CO The instrument does not come equipped with a sample flow rate sensor.
  • Page 3: Pneumatic Connections

    “From Purge” is the exhaust port for the for the purge gas. The gas needs to exhausted with a gas line not more than 10 meters long. In addition, the GFC7000EU uses a different sample pressure sensor than the GFC7000E. The GFc7000EU pressure sensor is rated for oxygen service. The part number is listed in the appendix –...
  • Page 4 MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) There are 4 relay alarm outputs (AL1-AL4) on the rear panel. AL1 is for system okay, AL2 is for concentration limit 1 exceeded and AL3 is for concentration limit 2 exceeded.
  • Page 5 MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) SAMPLE WHEEL TEMP WARNING CO = XX.XX TEST deactivates Warning Messages until New warning(s) TEST SETUP are activated MSG activates Warning SAMPLE RANGE=50.0 PPM CO = XX.XX Messages.
  • Page 6 MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) Warning Fault Condition Possible Causes Message FRONT PANEL The CPU is unable to WARNING only appears on Serial I/O COM Port(s) WARN Communicate with Front Panel Display will be frozen, blank or will not the Front Panel respond.
  • Page 7: System Reset

     Relay controlling the Wheel Heater  Entire Relay Board  I C Bus APPENDIX B – GFC7000EU Spare Parts List NOTE Use of replacement parts other than those supplied by API may result in non-compliance with European standard EN 61010-1.
  • Page 8 MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) #N05ATI 009690000 Filter, TFE, 47 mm 5 um, Qty 100 009690100 Filter, TFE, 47 mm 5 um, Qty 25 009820200 Assy, Motor, Synchronous, 115V/60HZ, "E" 010790000 Input Mirror...
  • Page 9: Part Number Description

    MODEL GFC7000EU CO ANALYZER WITH AUTO-REFERENCE (Addendum to GFC7000E Manual PN 04584) OR0000001 O-Ring, Flow Control OR0000058 O-Ring, Sample Filter, 47 mm, 2-228V OR0000034 O-Ring, Input/Output Mirror/Detector OR0000039 O-Ring, Window OR0000041 O-Ring, Field and Objective Mirror 043590100 Pump, 115V 50/60 Hz...