8.3

Timer Programming

A built-in timer allows you to automatically receive and transmit files. 10 timer programs can
be registered. To enable timer operation, see section 10-6.
8.3.1

Registering timer programs

1. Press the function key F5 and the 2 key to display the Timer Operation Entry screen.
Operation
Station
Start Time
Stop Time
Receive/Send
File to Send
2. If Create is not underlined, press →, ↑ and the Enter key to underline it.
3. Operation is selected. Enter a suitable operation name on the Operation line. Any
alphanumeric characters may be used.
Note: If the operation name entered already exists, the display "Operation
4. Press the ↓ key to choose Station.
5. Press the → key to display the Station List (which you registered stations in the previous
paragraph.)
6. Choose a station and press the Enter key.
7. Press the ↓ key to choose Start Time. Enter start time, in 24-hour notation. To have the
operation start at 8:35 a. m., for example, the keying sequence would be;
0
8
3
5
8. Press the ↓ key to choose Stop Time. Enter stop time, in 24-hour notation.
9. Press the ↓ key to choose Receive/Send. Choose operation category; Receive or Send.
If you have chosen "Send," go to step 10. For "Receive," go to step 12.
10. For send, insert the floppy disk which you want to send in the floppy drive, press the ↓
key to choose File to Send.
11. Press the → key to display the TX window, choose a file, and press the Enter key twice.
12. Press the Enter key.
13. Press the Enter key. The operation name appears in the Timer Operation List.
14. To enter another timer program, press the Enter key twice and the repeat steps 3-11.
15. Press the Esc key to finish.
Timer Operation Entry
Timer Operation List
Timer Operation Set Up
: _
:
:
0: 00: 00
:
0: 00: 00
: Receive Send
:
Press [→] to show station list, file list.
Timer operation entry screen
name already exists. Press any key to escape." Press any key and
change the operation name.
0
0
8. NBDP PREPARATIONS
Create
Change
8-5