Other Wear And Tear Parts - Pentair FOLEO 5800 XTR Installer Manual

Hide thumbs Also See for FOLEO 5800 XTR:
Table of Contents

Advertisement

Installer manual Foleo 5800 XTR - Maintenance
8.5.7

Other wear and tear parts

8.5.7.1
DLFC cleaning
1. Remove the softener cover, see First steps [
[
Page 75].
2. Remove the DLFC locking clip
3. Insert one of the pin of the DLFC locking clip
the DLFC housing (4).
4. Clean DLFC
(2)
using a soft brush or compressed air.
5. Lubricate the seal
Caution - material
Using another type of lubricant, such as petroleum-based lubricants (Vaseline, oils, or
hydro-carbon-based lubricants) or silicone grease, may damage the valve.
6. Reverse above procedure steps to rebuild.
8.5.7.2
Motor replacement
1. Remove the softener cover, see Softener cover removal [
2. Disconnect the optical sensor (3).
3. Open the motor clips
Caution - material
Do not pull on motor cables to extract the motor from its location.
82 / 108
(1)
and the DLFC housing (4).
(3)
with approved P-80® Emulsion lubricant only.
(1)
and pull out the old motor (2).
Page 74] and Softener cover removal
(1)
in the DLFC washer
Page 75].
Ref. MKT-IM-038 / E - 22.10.2021
(2)
and extract it from

Advertisement