Troubleshooting; Controller; Error Detection; Error Alerts - Pentair FOLEO 5800 XTR Installer Manual

Hide thumbs Also See for FOLEO 5800 XTR:
Table of Contents

Advertisement

Installer manual Foleo 5800 XTR - Troubleshooting
9

Troubleshooting

9.1

Controller

9.1.1

Error detection

If an error in valve or controller function occurs, an alarm will sound and the home screen will
display the error alert button
Press the alarm button
Press the error alert button
If the display is in sleep mode when an error occurs, the screen will turn on for five minutes. The
controller will beep once every 10 seconds until the error is cleared. If the error is not cleared
after five minutes, the screen will switch to power saving mode and display the error alert button
as a screen saver.
9.1.2

Error alerts

Info
An error alert appears on the home screen if an error condition is detected. Press the
error alert button
Most error alerts are cleared at regeneration. If the error persists following a
regeneration attempt the appropriate reset and recovery procedure below or contact
technical support.
Error screen
display
Optical Sensor
Undesired change
detected in the
optical sensor
Flow meter error
Continuous Flow
92 / 108
and the alarm button
Water Treatment
wed
12:01 am
rapid rince
backwash
to mute the alarm.
to view information about the error.
to view the error message.
Cause
An undesired optical
sensor state change
occurred.
The flow meter has
reported continuous
flow for more than 8
hours.
.
2 d
treatment
tank refill
pause
draw
Reset and recovery
Non-critical error. Extra optical sensor pulse
detected. Press the Regeneration button to advance
motor to clear error.
Error will cleared when flow to meter rise above 0.5
GPM or 1 Lpm. If continuous flow is ex-pected, turn
plumbing leak detection off in Master Settings. If not,
check for piping leaks.
Ref. MKT-IM-038 / E - 22.10.2021

Advertisement

Table of Contents
loading