cl generation/low salt: Set to on.
regen. interval: Contains the setting for the chlorine generation interval. Set up from 1 to 255 to
define the interval of regeneration between each chlorination activation, e.g. 1 so that it is enabled
at every regeneration or 10 so that it is activated every 10 regenerations for instance.
Mandatory
To be programmed upon local regulation and inlet water quality. In case no information
is available, it is advised to set "regen interval" at 4.
If bacterial growth issue is however noticed, reduce the interval.
Press
to save and to return to the master settings screen or press
settings screen without saving.
5.4.11

Non-factory setting

After all parameters in master setting have been set, press
display the non-factory settings screen.
Press
to save all programmed master settings parameters to non-factory settings. At any
point, the controller can be reset to these saved custom settings (see Error log [
Press
to return to the master settings screen without saving.
Info
By performing a custom reset, any setting that is subsequently programmed without
saving to non-factory settings will be reset to the previously saved non-factory settings
in the controller.
Ref. MKT-IM-038 / E - 22.10.2021
Chlorine Gen./Low Salt
cl generation/
low salt
regen. interval
Non-factory settings
current settings will
be saved as
the non-factory settings?
Installer manual Foleo 5800 XTR - Programming
on
4
to return to the master
on the master settings screen to
Page 61]).
59 / 108