Installer manual Foleo 5800 XTR - Troubleshooting
Issue
Cause
Reset and recovery
Brine tank overflow. Valve fails to draw brine in brine
Check for seals & spacers integrity.
draw cycle.
Clean or replace if necessary.
Check upper screen cleanliness.
Clean or replace if necessary.
Check inlet pressure. Make sure it is
above 1.4 bar dynamic.
Check safety brine valve and air
check. Clean, repair or change if
necessary.
Check for leak/air intake in brine
line. Change if necessary.
Check if brine line is not plugged or
partially obstructed. Remove plug if
necessary.
Check if drain line is not plugged or
partially obstructed. Remove plug if
necessary.