Screen name Parameters
Setting
review
Water Saver
Water saver
Regen
regen.
Remote
Remote
regeneration
signal
duration
Cl generation
Cl generation
Low salt
Low salt
Regen
interval
5.3

Touchscreen controller quick start

Info
Press
on any quick start screen to reset the screen back to its default settings,
excepted on the "Assistance interval" screen.
Steps Assistance name screen [
are optional and are not required to start the system. All controller settings may be
changed after the unit is in service.
If the screen is blank after plugging in the unit, touch the screen to turn the screen on.
Ref. MKT-IM-038 / E - 22.10.2021
Values
Displays a summary of all programmed settings.
Off
Off
On
/
1 – 255 Regeneration
Page 44] and Assistance phone screen [
Installer manual Foleo 5800 XTR - Programming
Notes
Chlorine generation together with low salt
detection will be performed during brine
draw cycle.
This parameter determines the
regeneration frequency on which there
will be chlorine generation.
Low salt detection will be performed
during regenerations indifferently of the
frequency set for cl generation.
Salt alarm will not avoid scheduled
regenerations to be performed.
To be programmed upon local regulation
and inlet water quality. In case no
information is available, it is advised to set
"Regen interval" at 4.
If bacterial growth issue is however
noticed, reduce the interval.