Startup; Cleaning, Disinfection And Sanitization; Cleaning Of Softeners; Disinfection With Sodium Or Calcium Hypochlorite - Pentair FOLEO 5800 XTR Installer Manual

Hide thumbs Also See for FOLEO 5800 XTR:
Table of Contents

Advertisement

Installer manual Foleo 5800 XTR - Commissioning
3. Once the draw function is observed and confirmed (level of water in the brine tank or cabinet
has decreased), you may go through each remaining cycles pushing on the regen button until
rapid rinse. Leave the complete cycle run to be sure that the brine draw in the system during
draw test is rinsed out.
6.1.3

Startup

1. Fill the brine tank in the cabinet with salt.
2. Adjust the safety brine valve in the brine well to make sure the overflow elbow is installed
above the float level.
3. After the softener has been running a few minutes in service, proceed to hardness test on
outlet water to make sure the water is treated as per requirements, and eventually adjust the
mixing device accordingly.
Info
Pentair advise to set a residual hardness between 50 and 100 mg/L of CaC0
6.2

Cleaning, disinfection and sanitization

The construction materials of the modern water softener will not support bacterial growth, nor
will these materials contaminate a water supply. During normal use, a softener may become
fouled with organic matter, or in some cases with bacteria from the water supply. This may result
in an off-taste or odour in the water. In this case, the tank of the softener must be cleaned and
disinfected.
Some softeners may need to be disinfected after installation and some softeners will require
periodic disinfection during their normal lifetime.
Depending on the conditions of use, the softener type, the type of ion exchanger, and the
disinfectant available, a choice can be made among the following methods.
6.2.1

Cleaning of softeners

Make sure the brine tanks remains free from debris, waste, scraps that could be drown in the
valve during brine draw cycles of regenerations. Make sure the softener and its parts remains
clean to ensure proper function. Note that camshaft positioning is made by a optical sensor.
Should this optical sensor be obstructed, malfunctions may happen.
6.2.2

Disinfection with sodium or calcium hypochlorite

These materials are satisfactory for use with polystyrene resins, synthetic gel zeolite, greensand
and bentonites.
6.2.2.1
5.25% Sodium hypochlorite
If stronger solutions are used, such as those sold for commercial laundries, adjust the dosage
accordingly.
Dosage
Polystyrene resin: set 1.25 mL per liter of resin.
64 / 108
.
3
Ref. MKT-IM-038 / E - 22.10.2021