Sanitization By Electrochlorination Process - Pentair FOLEO 5800 XTR Installer Manual

Hide thumbs Also See for FOLEO 5800 XTR:
Table of Contents

Advertisement

Brine tank softeners
Backwash the softener and add the required amount of hypochlorite solution to the well of the
brine tank. The brine tank should have water in it to permit the solution to be carried into the
softener.
Proceed with the normal regeneration.
6.2.2.2
Calcium hypochlorite
Calcium hypochlorite, 70% available chlorine, is available in several forms including tablets and
granules. These solid materials may be used directly without dissolving before use.
Dosage
Measure 0.11 mL per liter of resin.
Brine tank softeners
Backwash the softener and add the required amount of hypochlorite to the well of the brine tank.
The brine tank should have water in it to allow the chlorine solution from being carried into the
softener.
Proceed with the normal regeneration.
6.2.3

Sanitization by electrochlorination process

Optionally an electrochlorination device can be installed and coupled with the unit if not already
fitted.
Contact your supplier for more information.
Ref. MKT-IM-038 / E - 22.10.2021
Installer manual Foleo 5800 XTR - Commissioning