Table 11. Compressor Settings - Bogen NQ-A4060-G2 Configuration Manual

4-channel audio power amplifier
Hide thumbs Also See for NQ-A4060-G2:
Table of Contents

Advertisement

Note: If you want to return to the factory settings, select the
the right corner.
5
Select
Enable
to apply the settings to the selected channel.
Enable
Threshold
Attack
Hold
Decay
Knee

Table 11. Compressor Settings

Enables or disables the compressor DSP effect for this
channel.
Sets the threshold level, which is the point where the
signal activates the compressor circuit.
The range is -135 to +21 dB.
Sets how quickly or slowly compression will be applied
to the signal once the audio signal goes above the
threshold level. It specifies the length of time over which
the compression ratio will gradually increase from no
compression to full compression.
The range is 1 to 500 ms.
Sets how long compression will be applied after the sig-
nal has fallen below the threshold.
The range is 1 to 500 ms.
Sets how quickly or slowly compression will be removed
from the signal after the signal has dropped below the
threshold and the Hold interval has expired. It specifies
the length of time over which the compression ratio will
gradually decrease from full compression to no com-
pression.
The range is 0 to 2000 ms.
Sets how far below the threshold compression will begin
to be gradually applied to the signal. A very low value,
known as a hard knee, immediately applies full compres-
sion once the threshold is reached. A high value, known
as a soft knee, will gradually start applying compression
before the signal reaches the threshold, not reaching
the full effect until the threshold is reached, thereby
"rounding off" the compression effect. Increasing the
knee level decreases the obvious transition from the
uncompressed to the compressed sound.
The range is 1 to 100 dB.