Safety And Regulatory Compliance - ADTRAN Total Access 374 Installation And Maintenance Manual

4-pots, 4-gige mdu ont
Hide thumbs Also See for Total Access 374:
Table of Contents

Advertisement

Total Access 374 4-POTS, 4-GigE MDU ONT Installation and Maintenance Guide

Safety and Regulatory Compliance

!
WARNING
■ Read all warnings and cautions before installing or servicing this
equipment.
■ The protective earth (PE) grounding wire for this product must be 6 AWG
(13.3 mm
used in conjunction with an anti-rotation device. The connector must be a
suitably approved ground wire connector.
C
CAUTION
This product uses a Class 1 Laser module that complies with 21 CFR 1040.10
and 1040.11 and IEC 60825-1 and -2. For continued compliance with the above
standards, install only ADTRAN-approved Class 1 Laser Modules in this
product.
!
CAUTION
Electrostatic Discharge (ESD) can damage electronic modules. When
handling modules, wear an antistatic discharge wrist strap to prevent
damage to electronic components. Place modules in antistatic packing
material when transporting or storing. When working on modules, always
place them on an approved antistatic mat that is electrically grounded.
!
CAUTION
■ This product is intended to operate in ambient temperatures up to 65°C in
restricted access locations Only. This product is also intended to operate in
ambient temperatures up to 46°C in all other locations.
■ This equipment contains no parts that can be serviced by the user.
NOTE
■ Power supply input and output conductors of equipment, and signal
conductors of equipment which are exposed outside of the building, are
intended to be less than 140 feet (42.6 meters) in length and have adequate
clearance from power and lightning conductors in accordance with NEC
725 and 800. Final acceptance of the Listed equipment installation will
ultimately be up to the local Authority Having Jurisdiction (AHJ).
■ This product is designed to operate with a nominal operating voltage of 12
VDC.
1-4
2
) copper and utilize either a two-hole or a one-hole lug that is
C A U T I O N !
C A U T I O N
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
61287703G1-5B