ADTRAN 1203019L2 User Manual
ADTRAN 1203019L2 User Manual

ADTRAN 1203019L2 User Manual

Nt1 ace user manual international power supply 203019l1, 1203019l2, 1203019l3, 336048vur-2

Advertisement

Quick Links

1203019L1:
1203019L2:
1203019L3:
336048VUR-2:
61203019L1-1D
January 1999
NT1 ACE

USER MANUAL

NT1 ACE with Power Supply
NT1 ACE
NT1 ACE International
Power Supply

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN 1203019L2

  • Page 1: User Manual

    1203019L1: 1203019L2: 1203019L3: 336048VUR-2: 61203019L1-1D January 1999 NT1 ACE USER MANUAL NT1 ACE with Power Supply NT1 ACE NT1 ACE International Power Supply...
  • Page 2 CS03, Part I Section 1.4.2. ADTRAN will repair or replace this product within five years from the date of shipment if it does not meet its published spec- ifications or fails while in service. For detailed warranty, repair, and return information, refer to the ADTRAN Equipment War- ranty and Repair and Return Policy Procedure.
  • Page 3 4. If experiencing difficulty with this equipment, please contact ADTRAN for repair and warranty information. The telephone company may require this equipment to be disconnected from the net-...
  • Page 4 work until the problem is corrected, or it is certain the equipment is not malfunctioning. 5. This unit contains no user-serviceable parts. 6. An FCC compliant telephone cord with a modu- lar plug is provided with this equipment. In addi- tion, an FCC compliant cable appropriate for the dial backup option ordered is provided with this equipment.
  • Page 5 ADTRAN YEAR 2000 (Y2K) READINESS DISCLOSURE ADTRAN has established a Year 2000 program to ensure that our products and operations will correctly function in the new millennium. ADTRAN warrants that all prod- ucts meet Year 2000 specifications regardless or model or revision.
  • Page 6 CANADIAN EMISSIONS REQUIREMENTS This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard enti- tled "Digital Apparatus," ICES-003 of the Department of Communications. Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Class B prescrites dans la norme sur le materiel brouil- leur: "Appareils Numeriques,"...
  • Page 7 some cases, the company’s inside wiring associated with a single-line individual service may be extended by means of a certified connector assembly (telephone extension cord). Compliance with the above conditions may not prevent degradation of service in some situa- tions. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier.
  • Page 8 The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to pre- vent overloading. The termination on a loop may consist of any combination of devices subject only to the require- ment that the total of the Load Numbers of all devices does not exceed 100.
  • Page 9 AFFIDAVIT REQUIREMENTS FOR CONNECTION • An affidavit is required to be given to the tele- phone company whenever digital terminal equipment without encoded analog content and billing protection is used to transmit digi- tal signals containing encoded analog content which are intended for eventual conversion into voiceband analog signals and transmitted on the network.
  • Page 10 AFFIDAVIT FOR CONNECTION OF CUSTOMER PREMISES EQUIPMENT TO 1.544 MBPS AND/OR SUBRATE DIGITAL SERVICES For the work to be performed in the certified ter- ritory of _______________ (telco name) State of __________________ County of ________________ I, ______________________________(name), ________________________(business address), ______________________ (telephone number) be- ing duly sworn, state: I have responsibility for the operation and maintenance of the terminal equipment to be connected to 1.544 Mbps...
  • Page 11 ( ) The digital CPE does not transmit digital sig- nals containing encoded analog content or billing information which is intended to be decoded within the telecommunications network. ( ) The encoded analog content and billing pro- tection is factory set and is not under the control of the customer.
  • Page 12 ( ) C. An independent training course (e.g., trade school or technical institution) recognized by the manufacturer/grantee of the equipment used to encode analog signals; or ( ) D. In lieu of the preceding training require- ments, the operator(s)/maintainer(s) is (are) un- der the control of a supervisor trained in accordance with _________ (circle one) above.
  • Page 13 IMPORTANT SAFETY INSTRUCTIONS When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons. The precautions are listed below. 1. Do not use this product near water (for exam- ple, near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool).
  • Page 14 NT1 ACE User Manual 61203019L1-1...
  • Page 15: Table Of Contents

    Table of Contents Unit Overview ... 1 LED Indicators ... 2 Passive Bus Description ... 3 Inspection ... 3 Maintenance ... 4 Remote Testing ... 4 Repair and Return ... 4 Setting the Option Switches ... 4 Powering TEs from the NT1 ACE ... 6 Powering with the NT1 Power Supply ...
  • Page 16 Network Compatibility ...13 Mechanical ...13 Power ...13 Environmental ...13 Power Supply Specifications ...13 Figure 1. ADTRAN NT1 ACE ...1 Figure 2. Interface Connectors ...1 Figure 3. Switch Locations ...4 Figure 4. Power Supply Connection ...7 Figure 5. Short Passive Bus Configuration ...9 Figure 6.
  • Page 17: Unit Overview

    Unit Overview The ADTRAN NT1 ACE provides a basic rate interface between customer ISDN terminal equipment (TE) and the ISDN network (U). Figure 1 is an illustration of the NT1 ACE. Two jacks are provided on the rear panel of the unit for this purpose, as illustrated in Figure 2.
  • Page 18: Led Indicators

    ITU-TI.430 Recommendation Standard. The S/T-interface complies with ANSI T1.605 and ETSI ETS 300012 Stan- dard. The ADTRAN NT1 ACE is a stand-alone unit. An external power source must be provided for the NT1 ACE. External power is supplied by the ADTRAN Power Supply, part number 336048VUR-2.
  • Page 19: Passive Bus Description

    After unpacking the unit, immediately inspect it for possi- ble shipping damage. If damage is discovered, file a claim immediately with the carrier; then contact ADTRAN Cus- tomer Service. If possible, keep the original shipping con- tainer for use in shipping the NT1 ACE for repair or for verification of damage during shipment.
  • Page 20: Maintenance

    Repair and Return Repairs should not be performed in the field. Repair services can be obtained by returning the unit to the ADTRAN Cus- tomer and Product Service (CAPS) Department at the address listed on the inside back cover of this manual.
  • Page 21 The switch labeled TERMINATION sets the Local Bus ter- mination. The options available are NONE, 50, and 100. See Powering TEs from the NT1 ACE on page 6 for more informa- tion concerning Local Bus configurations. The switch labeled CONFIGURATION has two possible options.
  • Page 22: Powering Tes From The Nt1 Ace

    NT1 ACE User Manual Powering TEs from the NT1 ACE The ADTRAN NT1 ACE can be used to provide power for TEs connected to the local interface. The NT1 ACE, part number 1203019L1, supplies power by a separate wire pair (PS2) on the two data jacks marked LOCAL, as shown in Figure 2 on page 1.
  • Page 23 powered from the NT1, verify that the total power require- ment of the connected TE is less than 8.9 watts. To connect the NT1 ACE to the NT1 Power Supply, perform the following steps as illustrated in Figure 4. 1. Connect the Power Supply to the NT1 ACE at the POWER jack located on the NT1 ACE.
  • Page 24: Connecting The Terminal Equipment

    NT1 ACE User Manual Connecting the Terminal Equipment After successfully powering up the NT1 ACE, the POWER and ERROR indicators should be on and the READY indica- tor should be flashing. Make sure that terminal equipment (TE) is properly terminated as instructed in Setting the Option Switches on page 4.
  • Page 25: Short Passive Bus Configuration

    Short Passive Bus Configuration This configuration allows you to connect up to eight TEs at any point on the bus. The bus length is limited to 600 feet, as shown in Figure 5. To select the Short Passive Bus configu- ration, the CONFIGURATION switch must be set to the SHORT position.
  • Page 26: Extended Passive Bus Configuration

    NT1 ACE User Manual Extended Passive Bus Configuration This configuration allows you to connect up to eight TEs at greater ranges than the Short Passive Bus. This group of TEs can be located at up to 3000 feet from the NT1, as shown in Figure 6.
  • Page 27: Troubleshooting

    Troubleshooting If your NT1 ACE does not operate properly, please check the lists of symptoms and solutions below. For further assis- tance, please contact ADTRAN technical support at 888- 4ADTRAN. POWER indicator does not illuminate. • Verify power connection. • Move power supply to another circuit.
  • Page 28: Specifications

    NT1 ACE User Manual READY indicator does not illuminate. • Problem with ISDN network: Contact telephone company. • ISDN line not plugged into NETWORK jack: Plug ISDN line into NETWORK jack. Unable to make or receive a call. • TE is not compatible with ISDN network: Contact telephone company.
  • Page 29: 61203019L1-1 Nt1 Ace User Manual

    Faceplate Indicators ERROR ... U-interface or S/T interface not ready READY ... Steady light - Network ready to place a call POWER ... Unit has power Network Compatibility Interface ... ISDN Mechanical Size... 6.25" wide, 3.75" long, 1.35" high Weight ... 9.5 ounces Mounting...
  • Page 30 NT1 ACE User Manual NT1 ACE User Manual 61203019L1-1...
  • Page 31 Technical Support Repair and Return If ADTRAN Technical Support determines that a repair is needed, Technical Support will coordinate with the Customer and Product Service (CAPS) department to issue an RMA number. For information regarding equipment currently in...

This manual is also suitable for:

1203019l3203019l1336048vur-2Nt1 ace

Table of Contents