Siemens 6SN1123-1AA00-0DA2 Configuration Manual page 389

Simodrive 611 series drive converter
Table of Contents

Advertisement

11 Spare Parts and Service
11.4 Inspection of the DC link capacitors of the PM modules
Forming circuit
!
11-388
The forming circuit is configured using incandescent lamps, or alternatively us-
ing PTC resistors.
Components required (recommendation):
S
1 fuse switch 3x 400 V / 10 A
S
2
Cable, 1,5 mm
S
3 PTC resistors 350 R / 35 W
(Recommended: PTC–35W PTC800620–350 Ohm, company, Michael Koch
GmbH; www.koch–mk.de
S
3 incandescent lamps 230 V / 100 W
S
Various small parts, such as lamp sockets, etc.
Danger
As a result of the DC link capacitors, after the device has been disconnected
from the supply, voltages are present in the device for up to 5 min. It is only
permissible to work on the device or the DC link terminals at the earliest after
this wait time has expired!
Power module
Power module to be formed
Fig. 11-1
Forming circuit comprising power modules with incandescent lamps
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Fuse switch
Incande-
scent lamps
Motor connection
U2
V2
W2
PE
© Siemens AG 2012 All Rights Reserved
02.12
05.01
3 AC 400 V
L1
L2
L3
PE