Technical data

6.4.1

General information

The configuring of the infeed modules requires the performance data from the
Tables 6-9 and 6-10 and the following performance curves.
P/P
rated




1
0
300
320
Fig. 6-9
Normalized power graph
Note
When connected to line supplies with voltage fluctuations below the rated volta-
ge, the infeed should be overdimensioned corresponding to the above diagram
(Fig. 6-9), otherwise this can lead to failures or defects.
Table 6-7
cos ϕ: The power factor only contains the basic fundamental
λ: The power factor contains the basic fundamental and harmonic components
1) Is valid for sinusoidal current operation at the rated voltage without filter
Note
With line filter, when the converter is operating at partial load, a capacitive pha-
se shift occurs.
As line supplies in companies generally have an inductive phase shift, this ca-
pacitive component has a compensating effect in this line supply.
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
340
360
380
400
Power factory at the rated power without filter
Module
Operation on the line side
I/R
Sinusoidal current operation
I/R
Squarewave current operation
UE
6.4 Technical data
 P
max. block unregulated
 P
max. sine
 P
S6
 P
rated
420
440
460
480
Factor cos ϕ
cos ϕ  0.98
cos ϕ  0.98
cos ϕ  0.87
6 Infeed Modules
V
[V]
line supply
Factor λ
1)
λ  0.97
λ 0.89
λ  0.67
6-165
6