Siemens 6SN1123-1AA00-0DA2 Configuration Manual page 320

Simodrive 611 series drive converter
Table of Contents

Advertisement

02.12
05.01
Schematic diagram
F
(T10 A)
N
Filter (X kW)
F
(X A)
L
N
K
L1
L2
L3
PE
Fig. 8-36
Example for correct six–conductor connection to the line supply + DC link connection
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
8.15 Examples of correctly and incorrectly connecting NE
Correct for NE
NE
e.g. NCU PMxx
X181
M500
P500
2U1
1U1
2V1
1V1
2W1
1W1
Twisted
cable
P600
M600
U1
V1 W1
PE
Six–conductor connection
to the line supply
with DC link buffering
8 Important Circuit Information
w
16 kW!
PMxx
MM
X181
M500
P500
2U1
1U1
2V1
1V1
2W1
1W1
8
8-319