Nxt 6500, 70:1 Pump Modules - Graco Therm-O-Flow 20 Instructions - Parts Manual

Hide thumbs Also See for Therm-O-Flow 20:
Table of Contents

Advertisement

NXT 6500, 70:1 Pump Modules

420
401
432
403
2
413
1
Torque to 50-60 ft-lbs (68-81
N•m).
2
Torque to 145-155 ft-lbs (196-210 N•m).
3
Coat mounting surface of sensor mounting block with
non-silicone heat sink compound. Do not coat sensor.
4
Prior to tightening band clamp (412), RTD sensor (410)
must be fully contained within the sensor mount (411).
334129S
423
402
5
407a
403
429
409
430a
404
6
7
430b
414
431
1
405
5
Coat inside of heater (407a, 407b) only to within 3/4 in. of
vertical ends with non-silicone heat sink compound before
mounting.
6
Torque to 150 ft-lbs (203 N•m).
7
Apply anaerobic sealant.
408
406
1
418
419
417
415
416
4
410
411
3
4
412
5
407b
5
422
Parts
429
333
81

Advertisement

Table of Contents
loading

Table of Contents