Install Heated Hose - Graco Therm-O-Flow 20 Instructions - Parts Manual

Hide thumbs Also See for Therm-O-Flow 20:
Table of Contents

Advertisement

Install Heated Hose

To connect a hose to a fluid control device or heated
manifold.
1. Install fitting and heated hose onto Pump outlet
with the large electrical connector side toward the
system. Use 2 wrenches to tighten hose. Torque to
45 ft-lbs (61 N•m).
NOTE: See Accessories and Kits, page 88, for
available fittings and heated hoses.
F
. 10
IG
2. Wrap exposed fittings on the Pump outlet with
Nomex insulation and secure insulation using
fiberglass tape.
3. Connect large heated hose connector to MZLP.
F
. 11
IG
334129S
4. Repeat for any remaining channels.
5. Install cap on any unused MZLP electrical
connectors.
Connect the small 8 pin connector from the heated
6.
hose to the fluid control device or heated manifold.
F
. 12: Heated Manifold 243697
IG
NOTE: The heated manifold (part no. 243697) shown.
See Accessories and Kits, page 88, for available
manifolds and fluid control devices.
7. Use 2 wrenches to tighten hose. Torque to 45 ft-lbs
(61 N•m).
8. To connect multiple devices, see Connect Multiple
Devices, page 18.