NOTE: If work needs to be performed on the Ram
portion, perform the following additional steps to relieve
any trapped air in the inactive portion of the Ram.
9. Validate that the Heated Pump is fully supported
and is resting on the bottom plate.
10. Toggle the Ram Director Valve up and down to
relieve any trapped air.
334129S

Stop Controls

Normal Stop Control
To stop all electrical and most pneumatic processes,
press the System Shutdown button
the ADM.
All electrical operations will be shut down and the air
pressure to the Air Motor will be immediately relieved,
which will stop the movement of the Heated Pump.
Electrical components located in the main control box
will remain energized, but all operations will stop until
the system Enable/Disable button
pressed.
The Ram Director Valve will remain operable.
Air Motor and Heated Pump Stop
To stop only the Air Motor and Heated Pump, close the
Air Motor Slider Valve (CM). This is the preferred
method while changing drums.
Operation
located on
System Shutdown
has been
35