Load Material

NOTICE
To prevent damage to Platen wipers, do not use a pail
of material that has been dented or damaged. An
empty pail clamp can interfere with up and down
operation of the Ram. When raising the Ram, make
sure the pail clamp stays clear of the Platen.
NOTE: Before loading material, make sure there is a
minimum overhead clearance of 75 in. (191 cm) and all
air regulators are backed off to their full
counterclockwise position.
1. Open the Main Air Slider Valve (CA).
CA
2. Set Ram Director Valve (CC) to UP and slowly turn
the Ram Up Regulator (CD) clockwise until the
Platen (G) begins to rise.
F
. 19: Raise the Platen
IG
3. Apply a thin coating of high temperature grease
lubricant (part no. 115982) to the Platen pail seals.
334129S
4. Fill displacement Pump wet cup 2/3 full with Graco
Throat Seal Liquid (TSL™) for Butyl and PSA
materials.
NOTE: Use IsoGuard Select
for PUR or reactive Polyurethane material. IGS is
designed to dissolve and suspend the Polyurethane
materials. IGS will solidify after a period of time and
should be replaced once the solidified lube does not
return to liquid form after heating.
F
. 20: Wetcup
IG
5. Open pail, remove any packing material, and
inspect material for any contamination.
6. Slide the pail against the stops at the back of the
Ram baseplate.
CD
CC
F
. 21: Drum Placement
IG