Operation Screens

Home
This screen shows the temperature state of the system
and material usage.
NOTE: If present, secondary systems will be shown on
the home page.
Heat A
This screen shows the target and actual temperatures
for all zones on the system.
NOTE: The Heat-B screen shows information for an
optional secondary system.
NOTE: Mini-5 systems with software version 1.04.042
or later will not display pump data.
98
Color
White
Green
Red
Yellow
Green/Yellow Flashing
Events
The Events screens store a maximum of 200 events.
The events list can be downloaded in the USB logs.
See Appendix B - USB Data, page 105.
Tracked Events
Custom Language Downloaded
Custom Language Uploaded
Fill Valve Closed
Fill Valve Open
Heat Off
Heat On
Logs Downloaded
Pump Cycles Total Reset
Pump Off
Pump On
Red Stop Button Pressed
Setup Value Changed
System Power Off
System Power On
System Settings Downloaded
System Settings Uploaded
USB Disabled
USB Drive Inserted
USB Drive Removed
User Maintenance Count Reset
A and B Zone Status
Off
On and at setpoint
temperature
Outside of alarm range
Outside of advisory range
Warmup