Appendix A - ADM

Setup Screens

NOTE: It is important to set all settings in the System
screens correctly to ensure optimal system
performance.
Password
If the password is not "0000", the password must be
entered to access the setup screens.
System 1
External Pump Control: Enable feature that
automatically turns on and off the Pump when using a
handheld dispense gun with an integrated trigger
switch.
Enable Diagnostic Screen: Choose whether to show
the Diagnostic screen.
Enable Temp. Adjustments: Allows temperature
adjustments on the Heat-A and Heat-B Run screens.
Enable Pump Autostart: Automatically turns the Pump
on after reaching setpoint temperature and heat soak is
complete.
100
Enable Tandem System: Enable all secondary system
ADM screens.
Heat Soak: Time for to preheat after all zones have
reached their target temperatures. Pump cannot turn on
until timer is complete. The heat soak is a user-defined
time.
Range: 1-120 minutes
0 disables heat soak
Pump Inactive Timeout: If no Pump movement is
detected or either Pump for (x) amount of time, all
heated zones enter setback mode. After an additional
amount of time (x), the heat will turn off.
(x) Range: 0-120 minutes
0 disables heat soak
NOTE: The pump inactive timeout will not be displayed
on Mini-5 systems with software versions 1.04.042 or
later.
System 2
Enter low and high temperatures for an alarm or
warning to occur.
Advanced 1
334129S