Select ADM Settings

NOTE: See Appendix A - ADM, page 96 for detailed
ADM information, including general operation.
1. Turn Main Power Switch ON.
2. When the ADM is finished starting up, press
to switch from the Operation screens to the Setup
screens. Use the arrows to navigate between
screens.
3. Check system settings on the System 1 screen.
NOTE: Pump inactive timeout will not be shown on
Mini-5 systems with software version 1.04.042 or later.
334129S
4. Set alarm levels on the System 2 screen.
5. Set primary system setpoint and setback
temperatures for the Pump, Platen, and heat zones
on the Heat-A-screens.
NOTE: Setback temperatures must be at least 20°F
(10°C) lower than the setpoint temperatures.
NOTE: Pump setpoint and setback temperature will not
be shown on Mini-5 systems with software version
1.04.042 or later.
NOTE: To ensure accurate hose temperatures, be sure
all heated hoses have their "zone type" set to "Hose."
Hoses are only present on odd zone numbers: 1, 3, 5,
7, 9, or 11.
a. Select the appropriate "Zone Type" for all
installed zones.
b. Check the "A" and "B" boxes according to
which systems needs to use the heated
accessory.
Setup
23