InstALLAtIon
1-2

LOCATION

These merchandisers are designed for displaying
products in air conditioned stores where
temperature is maintained at or below the
ANSI/NSF-7 specified level and relative
humidity is maintained at or below 55%.
Placing refrigerated merchandisers in direct
sunlight, near hot tables or near other heat
sources could impair their efficiency. Like
other merchandisers, these are sensitive to
air disturbances. Air currents passing around
merchandisers will seriously impair their
operation. Do NOT allow air conditioning,
electric fans, open doors or windows, etc. to
create air currents around the merchandisers.
To prevent sweating on the exterior surfaces
of merchandisers, there must be
4
clearance of
inches
the merchandisers and other fixtures or walls.
A 5.5 inch (140 mm) space is required between
facade top and the ceiling. A louvered Facade
Panel kit is available that will allow for a
top spacing minimum clearance of 3 inches
(76 mm).
Product should always be maintained at proper
temperature. This means that from the time the
product is received, through storage, preparation
and display, the temperature of the product must
be controlled to maximize the life of the product.
Condensing units installed on top of the
merchandiser require air circulation to operate
properly. Blocking or restricting air flow will
adversely affect performance and may damage
the refrigeration system.
Do not store items or flammable
materials atop the unit.
Do not walk on case.
P/N 0539221_T
a minimum
(102
) between
mm
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM
When installed in a lineup, Hussmann
recommends that partitions be installed
between individual cases to prevent frost
buildup and other issues that might result
from different defrost schedules and operating
temperatures. These partitions may be acrylic
or insulated, depending on case's operating
temperature.
If the ceiling and/or walls are built up around the
merchandiser, allow for a sufficient gap above or
behind the merchandiser to provide adequate air
circulation. When merchandisers are installed in
a lineup, case must be taken to ensure that warm
condenser air is not blown from one unit into the
condenser of the adjacent unit.

SHIPPING DAMAGE

All equipment should be thoroughly examined for
shipping damage before and during unloading.
This equipment has been carefully inspected at our
factory. Any claim for loss or damage must be made
to the carrier. The carrier will provide any necessary
inspection reports and/or claim forms.
Apparent Loss Or Damage
If there is an obvious loss or damage, it must be
noted on the freight bill or express receipt and
signed by the carrier's agent; otherwise, carrier
may refuse claim. The carrier will supply necessary
forms.
Concealed Loss Or Damage
When loss or damage is not apparent until after
equipment is uncrated, a claim for concealed
damage is made. Upon discovering damage, make
request in writing to carrier for inspection within
15 days and retain all packing. The carrier will
supply inspection report and required claim forms.