REFRIGERATION / ELECTRICAL / CONTROLLER
2-4
Heated condensate pan
EVAPORATOR TO BE
PLUGGED INTO GFCI OUTLET
is to be plugged into GFCI
MOUNTED ON TOP RIGHT SIDE
outlet, mounted on top,
OF RACEWAY
right side of wireway

ABOUT QUICK CONNECT COUPLINGS

Quick Connect fittings are provided on
both the case inlet and outlet lines, and
on Hussmann's TCL and TCM series of
condensing units. The case and condensing
unit are pre-charged with the correct amount
of R404A refrigerant, and the lines are sealed.
Connecting the Quick Connects together
breaks the seals to connect the refrigeration
lines of the unit to the case. The Quick
Connects must be properly torqued to avoid
refrigerant leaks.

CONNECT LINES

Mount the suction line and liquid line to the
condensing unit. When ready to connect,
remove protector caps and plugs from the
Quick Connect Couplings.
P/N 0539221_T
Position heated condensate pan to
Dimensions shown and install (4)
POSITION EVAPORATOR TO DIMENSIONS SHOWN
SM Self-Drill Screws into Top Foam
AND INSTALL (4) SM SELF-DRILL SCREWS INTO
TOP FOAM PANEL LINER
Panel Liner
A
Condensate Pan Installation, Location and Electrical
If necessary, carefully wipe coupling seats and
threaded surfaces with a clean cloth to prevent
the inclusion of dirt or any foreign material in
the system.
Step 1:
Apply refrigerant oil to the entire surface of
diaphragm, o-ring and threaded area of male
coupling assembly. The amount of lubricant
used must cover all designated surfaces
sufficiently. Ideal application is a small
applicator brush saturated with lubricant and
applied liberally.
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM
View is looking at top of case, right side
VIEW LOOKING AT TOP OF CASE RH SIDE
Foam Seal must be in place, sealant must
be applied around the copper lines after
connecting the condensing unit.
(approximate
17 inches
location)
(432 mm)
17.00 APPROX.
9 inches
9.00
APPROX.
(229 mm)
Detail A