REFRIGERATION / ELECTRICAL / CONTROLLER
2-2

FIELD INSTALLATION OF CONDENSING UNIT

A mounting plate is provided on top of the
case with pilot holes that provide specific
attachment points for the condensing unit
base. The mounting plate is located above the
next to last door on the right.
Insulation Sponge 5/8 inch x 3/4 inch wall
insulation to cover entire length from
Condenser Unit connection to end of
copper tubing, where it enters at top of
case, including quick connects
Facades
Right side of case
looking from the front
P/N 0539221_T
Condensing Unit
5-Door Case & Condenser Unit Shown
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM
The condensate pan, if selected by the end
user, is packed inside the case and must also
be installed and leveled on top of the case,
then plugged into the 120V GFCI outlet
provided.
Exact component location is not critical;
however, the components should be mounted
in the general locations shown below to ensure
that electrical connections reach, and the
condensate pan has adequate air flow from the
condenser.
Orient the Condenser Unit as shown on top
of the case. Line up mounting holes on base
of condenser unit with holes on mounting
plate and secure using (4) 12-14 x 2 1/4 inch
screws and flat washers
Apply Rubber Gasket along base edges that
contact mounting plate (8) places (2 each
side) as shown
Rear Bracket used on 4 & 5 Door Cases Only.
Sound Panel Kits Use Similar Bracket For 3
Door Cases. Rear bracket not necessary for
RFLTM.
Connect quick connects on flexible liquid &
suction lines from condensing unit to quick
connects on pipes exiting top right of case