Controls And Adjustments - Hussmann RFLNS Installation & Operation Manual

Table of Contents

Advertisement

P/N 0539221_T
Model
RFLNS
RFLNS
RFMNS
RFLTM
1. The controller controls refrigeration
temperature. This is factory installed in the
control panel. Adjust this control keypad to
maintain the discharge air temperature shown.
Measure discharge air temperatures at the
center of the honeycomb.
For low temperature models, defrosts are time
initiated and temperature terminated. The
defrost setting is factory set as shown.
To ensure a thorough defrost, the defrost must
be terminated by the temperature termination
setting — not by time.
For medium temperature models, defrost is
time initiated and time terminated.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

CONTROLS and ADJUSTMENTS

Refrigeration
Controls
Discharge Air
Product
Temperature
Application
Frozen Food
-5° F
Ice Cream
-12° F
Medium Temp.
32° F
(Dairy, Deli)
Frozen Food
-5° F
Defrost Controls
Defrost
Type of
Frequency
Defrost
(per day)
1
Electric
1
Electric
1
O Time
Electric
1
Freedom Line Reach-in
2-15
Failsafe
Termination
Time
Temperature
(Minutes)
48°F
45
48°F
45
60
NA
45
48°F