UL LISTING

These merchandisers are manufactured to
meet ANSI/ UL 471 standard requirements
for safety. Proper installation is required to
maintain the listing.
FEDERAL / STATE REGULATION
These merchandisers at the time they are
manufactured, meet all federal and state/
provincial regulations. Proper installation
is required to ensure these standards are
maintained. Near the serial plate, each
merchandiser carries a label identifying the
environment for which the merchandiser was
designed for use.
In compliance with DOE 2017, standard low
temp Reach In cases with Innovator I Doors
are equipped with an anti-sweat controller that
maintains the door heat at a level that meets
DOE energy limits. Any factory or field-installed
anti-sweat controller applied to a low temp
Reach In case with Innovator I Doors must be
programmed to cycle the heaters at no more
than 50% run time at design conditions of 75
degrees, 55% RH for frozen food operating
condition.
ANSI/NSF-7 Type I – Display Refrigerator / Freezer
Intended for 75°F / 55%RH Ambient Application
ANSI/NSF-7 Type II – Display Refrigerator / Freezer
Intended for 80°F / 55%RH Ambient Application
ANSI/NSF-7 – Display Refrigerator
Intended for Bulk Produce
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
INSTALLATION

FREEDOM LINE DESCRIPTION

The Freedom Line RFLTM, RFLNS and
RFMNS cases are designed to be ready for
remote installation of a top-mounted air-cooled
condensing unit, such as Hussmann's TCLSA
through TCMSD series of condensing units.
They are controlled by an electronic control.
The case temperature is controlled by cycling
the compressor based on the discharge air
temperature input.
The sensor for this input is located above
the discharge air honeycomb. A defrost
termination sensor is located on the bottom,
center evaporator coil return bends.
The controller is pre-programmed for low or
medium temperature operation and may be
adjusted to desired operating temperature by
the control keypad.
Cases running on individual condensing units
may be installed as stand-alone cases with ends,
or as a part of a lineup.
Excessive ambient conditions may cause
condensation and therefore sweating of
doors. Facility operators should monitor
doors and floor conditions to ensure safety
of persons.
Freedom Line Reach-in