P/N 0520677_W

UL LISTING

These merchandisers are manufactured to
meet ANSI/ UL 471 standard requirements
for safety. Proper installation is required to
maintain the listing.
FEDERAL / STATE REGULATION
These merchandisers at the time they are
manufactured, meet all federal and state/
provincial regulations. Proper installation
is required to ensure these standards are
maintained. Near the serial plate, each
merchandiser carries a label identifying the
environment for which the merchandiser was
designed for use.
In compliance with DOE 2017, standard low
temp Reach In cases with Innovator I Doors
are equipped with an anti-sweat controller that
maintains the door heat at a level that meets
DOE energy limits. Any factory or field-installed
anti-sweat controller applied to a low temp
Reach In case with Innovator I Doors must be
programmed to cycle the heaters at no more
than 50% run time at design conditions of
75 degrees, 55% RH for frozen food operating
condition.
ANSI/NSF-7 Type I – Display Refrigerator /
Freezer
Intended for 75°F / 55%RH Ambient
Application
ANSI/NSF-7 Type II – Display Refrigerator /
Freezer
Intended for 80°F / 55%RH Ambient
Application
ANSI/NSF-7 – Display Refrigerator
Intended for Bulk Produce
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

INSTALLATION

FREEDOM LINE DESCRIPTION

These cases are designed to be ready for
remote installation of a top-mounted air-
cooled or water-cooled condensing unit. They
are controlled by an electronic control. The
case temperature is controlled by cycling
the compressor based on the discharge air
temperature input. The sensor for this input
is located above the interior top panel at the
right door. Another sensor, located on the
bottom center evaporator coil return bend, is
used for defrost termination. The controller is
programmed for low or medium temperature
operation, and is adjusted for the required
temperature by the keypad located on the front
of the controller, which is on the top of the
case.
Cases running on individual condensing units
may be installed as stand-alone cases with ends,
or as a part of a lineup. When installed in a
lineup, Hussmann recommends that partitions
be installed between individual cases to prevent
frost buildup and other issues that might result
from different defrost schedules and operating
temperatures.

LOCATION

These merchandisers are designed for
displaying products in air conditioned stores
where temperature is maintained at or below
the ANSI/NSF-7 specified level and relative
humidity is maintained at or below 55%.
Placing refrigerated merchandisers in direct
sunlight, near hot tables or near other heat
sources could impair their efficiency. Like
other merchandisers, these are sensitive to
air disturbances. Air currents passing around
merchandisers will seriously impair their
operation. Do NOT allow air conditioning,
electric fans, open doors or windows, etc. to
create air currents around the merchandisers.
Freedom Line Reach-in
Freedom Line Reach-in
1-1