Running Belt And Deck Replacement Procedure; About; Procedure - Precor Precision 400 Series Service Manual

Hide thumbs Also See for Precision 400 Series:
Table of Contents

Advertisement

Running Belt and Deck Replacement Procedure

About

This procedure provides instruction to remove and replace the Running Belt and Deck.
Belt and Deck
The running belt is a lubricated type belt and is used with a non-waxed deck. The deck is
reversible and not waxed.
CAUTION: Do not apply any lubricants or wax to the deck and belt. Do not use
Wax Blast, silicon sprays, or other applied lubricants. The use of these lubricants
will quickly degrade the low-friction surface of the deck.

Procedure

Review entire procedure before starting.
Removal
1. Switch the power OFF and
2. Remove the hood cover. Retain part(s) and/or fastener(s) for installation.
3. Remove the endcaps and belt guard covers from the rear of treadmill. Retain part(s)
and/or fastener(s) for installation.
4. Remove the left and right landing trim covers. Retain part(s) and/or fastener(s) for
installation.
5. Remove the left and right roller bridges. Retain part(s) and/or fastener(s) for install-
ation.
6. Remove the Take-up Roller, see
7. Remove the Drive Roller, see
8. Carefully lift the deck and belt out of the treadmill frame.
9. Remove the running belt from the deck and discard.
A new deck surface must be used with each new belt replacement.
If both sides of the deck are used, discard the deck, and replace with a new
l
deck.
If the bottom side of the deck has not been used (new), flip and use new side of
l
the deck.
Installation
1
Disconnect a device power cord plug or cable connector from the power receptacle or out-
let.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Running Belt and Deck Replacement Procedure
1
unplug
the power cord.
"Take-up Roller Replacement" on
"Drive Roller Replacement" on
6 Replacement Procedures
page 74.
page 71.