Cycle the power OFF/ON.
l
Wait for the power-up sequence to complete, then go to the Error Log
l
and verify that all active error codes errors have been cleared (press and
hold the PAUSE key for 5-6 seconds).
Press WORKOUTS or PAUSE to exit the Error Log.
l
Hardware Validation Tests Verification
Verify that each of the service menu Hardware Validation tests are successfully com-
pleted.
1. Access the Hardware Validation service menu (51765761) and perform the fol-
lowing tests, see
Select Test to start the test and Stop Test to exit.
Beeper
l
Keypad Test
l
LCD Test
l
Heart Rate Test
l
Machine Tests - Press Go to access the machine tests
l
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
"R20 How To Access Standard Service menus" on
Beep sounds once every second.
o
Press all keys and verify change to the pattern. The test will exit
o
when all keys have been pressed. Pressing down Workouts for 5
seconds also exits the test.
Test will light up all segments and sections of the display.
o
Heart rate is acquired and displayed
o
Belt Speed Test:
o
Range: 0.5 mph to 12.0 mph in 0.1 increments. in 0.1 increments.
Press Go to start the Belt Speed Test (IMPORTANT the run-
n
ning belt will start movint):
Use the SPEED control to verify operation through the min-
n
imum and maximum speed limits.
Range: 0.5 mph to 12.0 mph in 0.1 increments. in 0.1 incre-
ments.
Incline Test:
o
Use the incline control to raise/lower incline to verify the following
incline angle A/D values
Nominal A/D value: [[[Undefined variable Spe-
n
3 Operation Verification
R20 Operation Verification Test
page 39.